Ethernet embedded readout interface for Timepix2 – Katherine readout for Timepix2
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F20%3A43958530" target="_blank" >RIV/49777513:23220/20:43958530 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21670/20:00342086
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1748-0221/15/01/C01037" target="_blank" >https://iopscience.iop.org/article/10.1088/1748-0221/15/01/C01037</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1748-0221/15/01/C01037" target="_blank" >10.1088/1748-0221/15/01/C01037</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ethernet embedded readout interface for Timepix2 – Katherine readout for Timepix2
Popis výsledku v původním jazyce
This paper introduces a readout system for the Timepix2. Firstly, this chip is described and the readout modes are discussed in detail. The new readout system presented is based on the Gigabit Ethernet interface and implements pre-processing, i.e. decoding of the raw pixel data, directly in the hardware. The device suppresses zero pixels, so that only useful data are sent to the computer/server. In a special independent mode, the readout can send completed data files to a remote server via SSH and does not need to use a control software. In island mode, the device stores measured data to a local storage (SD card). The process of calibration and its results are also discussed. An energy resolution of approximately 1.5 keVwas achieved for 60 keVgamma-rays from an 241Am source. We present enhanced features of the readout system facilitating measurements and data evaluation, such as the HW support of clustering and Matrix Occupation Control. The former implements the pixel clustering directly in the hardware and sends energy calibrated results of the cluster finding algorithm to the computer. The latter automatically controls acquisition time of detector in order to reduce cluster overlapping. Measurements with Timepix2 are presented in iron and electron test beams. Results show that pixels of Timepix2 saturate at a per-pixel energy deposition of 1.9 MeV.
Název v anglickém jazyce
Ethernet embedded readout interface for Timepix2 – Katherine readout for Timepix2
Popis výsledku anglicky
This paper introduces a readout system for the Timepix2. Firstly, this chip is described and the readout modes are discussed in detail. The new readout system presented is based on the Gigabit Ethernet interface and implements pre-processing, i.e. decoding of the raw pixel data, directly in the hardware. The device suppresses zero pixels, so that only useful data are sent to the computer/server. In a special independent mode, the readout can send completed data files to a remote server via SSH and does not need to use a control software. In island mode, the device stores measured data to a local storage (SD card). The process of calibration and its results are also discussed. An energy resolution of approximately 1.5 keVwas achieved for 60 keVgamma-rays from an 241Am source. We present enhanced features of the readout system facilitating measurements and data evaluation, such as the HW support of clustering and Matrix Occupation Control. The former implements the pixel clustering directly in the hardware and sends energy calibrated results of the cluster finding algorithm to the computer. The latter automatically controls acquisition time of detector in order to reduce cluster overlapping. Measurements with Timepix2 are presented in iron and electron test beams. Results show that pixels of Timepix2 saturate at a per-pixel energy deposition of 1.9 MeV.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Instrumentation
ISSN
1748-0221
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
16
Strana od-do
0-15
Kód UT WoS článku
000525449100037
EID výsledku v databázi Scopus
2-s2.0-85081681606