Popis výsledku v původním jazyce
This article describes the results of an experiment in which a reference signal with its subsequent processing is used to obtain information on the degree of cable insulation degradation. A one-dimensional convolutional neural network is used for signal classification. The reference signal was tested with two methods of insulation degradation, thermal and electrical. The signal was preprocessed to obtain its power spectrum density. After that the obtained result was sent to the input of the neural network. Based on the learning and validation curves and the confusion classification matrices, the optimal frequencies of the reference signal were found.
Název v anglickém jazyce
Determination of the Optimal Reference Signal Frequency in the Task of Power Spectrum Pattern Classification
Popis výsledku anglicky
This article describes the results of an experiment in which a reference signal with its subsequent processing is used to obtain information on the degree of cable insulation degradation. A one-dimensional convolutional neural network is used for signal classification. The reference signal was tested with two methods of insulation degradation, thermal and electrical. The signal was preprocessed to obtain its power spectrum density. After that the obtained result was sent to the input of the neural network. Based on the learning and validation curves and the confusion classification matrices, the optimal frequencies of the reference signal were found.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2022 22nd International Scientific Conference on Electric Power Engineering (EPE 2022)
ISBN
978-1-66541-056-4
ISSN
—
e-ISSN
2376-5631
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
VSB - Technical University of Ostrava
Místo vydání
Ostrava
Místo konání akce
Kouty nad Desnou, Czech Republic
Datum konání akce
8. 6. 2022
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—