Carbon Nanotubes Decorated with Palladium Nanoparticles for Hydrogen Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F23%3A43968777" target="_blank" >RIV/49777513:23220/23:43968777 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/49777513:23640/23:43968777
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/10168452" target="_blank" >https://ieeexplore.ieee.org/document/10168452</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ISSE57496.2023.10168452" target="_blank" >10.1109/ISSE57496.2023.10168452</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Carbon Nanotubes Decorated with Palladium Nanoparticles for Hydrogen Detection
Popis výsledku v původním jazyce
This paper presents a hydrogen sensor based on single-walled carbon nanotubes (SWCNT) decorated with Pd nanoparticles. Pulsed laser ablation in water was used to prepare Pd nanoparticles in colloid form. Two types of samples were prepared using airbrush deposition technology: one containing only SWCNT and the other containing a combination of SWCNT and Pd nanoparticles. Experimental results show that Pd nanoparticles have a significant contribution to the sensitivity of the sensor, which shows a greater response to hydrogen gas at room temperature. In addition, the temperature dependence and cross-sensitivity of the sensor to other gases such as methane, ammonia and nitrogen dioxide were investigated.
Název v anglickém jazyce
Carbon Nanotubes Decorated with Palladium Nanoparticles for Hydrogen Detection
Popis výsledku anglicky
This paper presents a hydrogen sensor based on single-walled carbon nanotubes (SWCNT) decorated with Pd nanoparticles. Pulsed laser ablation in water was used to prepare Pd nanoparticles in colloid form. Two types of samples were prepared using airbrush deposition technology: one containing only SWCNT and the other containing a combination of SWCNT and Pd nanoparticles. Experimental results show that Pd nanoparticles have a significant contribution to the sensitivity of the sensor, which shows a greater response to hydrogen gas at room temperature. In addition, the temperature dependence and cross-sensitivity of the sensor to other gases such as methane, ammonia and nitrogen dioxide were investigated.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Spring Seminar on Electronics Technology
ISBN
979-8-3503-3484-5
ISSN
—
e-ISSN
2161-2536
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Piscaway
Místo konání akce
Timisoara, Romania
Datum konání akce
10. 5. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—