Accelerated Life Testing for Rotating Machine Insulating Materials Exposed to High AC Voltage
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F24%3A43973004" target="_blank" >RIV/49777513:23220/24:43973004 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/10693924" target="_blank" >https://ieeexplore.ieee.org/document/10693924</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/Diagnostika61830.2024.10693924" target="_blank" >10.1109/Diagnostika61830.2024.10693924</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Accelerated Life Testing for Rotating Machine Insulating Materials Exposed to High AC Voltage
Popis výsledku v původním jazyce
The Progressive Stress Method (PSM) and the Multi-Level Stress Method (MLM) are two crucial methodologies employed in studying the aging and failure mechanism of insulating materials subjected to high voltage stress. Each method has its pros and cons. The presented study highlights the importance of understanding the relationship between the Progressive Stress Method and the Multi-Level Stress Method in assessing the aging and failure of insulating materials. The findings revealed that for the investigated insulation material and chosen testing conditions, the aging process of insulation is remarkably similar under both stress methods. However, it is observed that at Progressive Stress Method the measured breakdown voltage is higher than in comparison with MLM. In some cases, the application of PSM leads to a shorter testing time procedure. Under certain conditions, the results obtained by PSM might be converted into MLM lifetime values which allows an effective approximation of lifetime characteristics for applied insulation materials.
Název v anglickém jazyce
Accelerated Life Testing for Rotating Machine Insulating Materials Exposed to High AC Voltage
Popis výsledku anglicky
The Progressive Stress Method (PSM) and the Multi-Level Stress Method (MLM) are two crucial methodologies employed in studying the aging and failure mechanism of insulating materials subjected to high voltage stress. Each method has its pros and cons. The presented study highlights the importance of understanding the relationship between the Progressive Stress Method and the Multi-Level Stress Method in assessing the aging and failure of insulating materials. The findings revealed that for the investigated insulation material and chosen testing conditions, the aging process of insulation is remarkably similar under both stress methods. However, it is observed that at Progressive Stress Method the measured breakdown voltage is higher than in comparison with MLM. In some cases, the application of PSM leads to a shorter testing time procedure. Under certain conditions, the results obtained by PSM might be converted into MLM lifetime values which allows an effective approximation of lifetime characteristics for applied insulation materials.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2024 International Conference on Diagnostics in Electrical Engineering (Diagnostika) : /conference proceedings/
ISBN
979-8-3503-6149-0
ISSN
2464-7071
e-ISSN
2464-708X
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Pilsen, Czech Republic
Datum konání akce
3. 9. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001345150300049