The aim of this study has been addressed to thoracic parts. The photographs of Visible Human project have been fundamental for the creation of organ's geometry. The models have been created by virtue of solid elements and biobags. The Amira software andHypermesh software have been used for creation of individual organ grids. The PAM-CRASH software has been utilized for the completion and following validation of the whole thoracic model. The material properties, which supported the geometry, have been obtained from the various sources, such as articles, books and internet. The thoracic model has been validated by virtue of frontal Kroell test with impact speed 4.9 m/s, 6.7 m/s and 9.9 m/s, respectively. The satisfactory results of the validation have been obtained. Therefore the following biomechanical simulation could be applied and the investigation of thoracic injury criteria could be started.
Název v anglickém jazyce
Biomechanical model of thorax
Popis výsledku anglicky
The aim of this study has been addressed to thoracic parts. The photographs of Visible Human project have been fundamental for the creation of organ's geometry. The models have been created by virtue of solid elements and biobags. The Amira software andHypermesh software have been used for creation of individual organ grids. The PAM-CRASH software has been utilized for the completion and following validation of the whole thoracic model. The material properties, which supported the geometry, have been obtained from the various sources, such as articles, books and internet. The thoracic model has been validated by virtue of frontal Kroell test with impact speed 4.9 m/s, 6.7 m/s and 9.9 m/s, respectively. The satisfactory results of the validation have been obtained. Therefore the following biomechanical simulation could be applied and the investigation of thoracic injury criteria could be started.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Biomechanics
ISSN
0021-9290
e-ISSN
—
Svazek periodika
—
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
1
Strana od-do
155
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—