TOWARDS MICROSTRUCTURE BASED TISSUE PERFUSION RECONSTRUCTION FROM CT USING MULTISCALE MODELING
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23520%2F12%3A43915765" target="_blank" >RIV/49777513:23520/12:43915765 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
TOWARDS MICROSTRUCTURE BASED TISSUE PERFUSION RECONSTRUCTION FROM CT USING MULTISCALE MODELING
Popis výsledku v původním jazyce
The paper deals with modeling of blood perfusion and simulation of dynamic CT investigation. The flow can be characterized at several scales for which different models are used. We focus on two levels: flow in larger branching vessels is described usinga simple "1D" model based of the Bernoulli equation. This model is coupled through point sources/sinks with a "0D" model describing multicompartment flows in tissue parenchyma. We propose also a model of homogenized layer which can better reflect arrangement of the microvessels. The research is motivated by modeling liver perfusion which should enable an improved analysis of CT scans. For this purpose we describe a dynamic transport of the contrast fluid at levels of the "1D" and "0D" models, so that time-space distribution of the so-called tissue density can be computed and compared with the measured data obtained form the CT.
Název v anglickém jazyce
TOWARDS MICROSTRUCTURE BASED TISSUE PERFUSION RECONSTRUCTION FROM CT USING MULTISCALE MODELING
Popis výsledku anglicky
The paper deals with modeling of blood perfusion and simulation of dynamic CT investigation. The flow can be characterized at several scales for which different models are used. We focus on two levels: flow in larger branching vessels is described usinga simple "1D" model based of the Bernoulli equation. This model is coupled through point sources/sinks with a "0D" model describing multicompartment flows in tissue parenchyma. We propose also a model of homogenized layer which can better reflect arrangement of the microvessels. The research is motivated by modeling liver perfusion which should enable an improved analysis of CT scans. For this purpose we describe a dynamic transport of the contrast fluid at levels of the "1D" and "0D" models, so that time-space distribution of the so-called tissue density can be computed and compared with the measured data obtained form the CT.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
10th World Congress on Computational Mechanics (WCCM2012)
ISBN
978-85-86686-70-2
ISSN
—
e-ISSN
—
Počet stran výsledku
18
Strana od-do
1-18
Název nakladatele
Universidade de Sao Paulo
Místo vydání
Sao Paulo
Místo konání akce
Sao Paulo, Brazílie
Datum konání akce
8. 7. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—