A Novel Method for Partial Rub Detection Based on Cumulation of Liftered Full Spectrum
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23520%2F14%3A43922072" target="_blank" >RIV/49777513:23520/14:43922072 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Novel Method for Partial Rub Detection Based on Cumulation of Liftered Full Spectrum
Popis výsledku v původním jazyce
Contemporary trend in design of turbomachinery leads to increase of efficiency through reducing the seal clearances. Tight rotor-to-seal clearance may lead to undesirable contact between rotating and stationary part of the machine, called simply rubbingor rub. The methods, standardly used for rub detection, are mainly based on observation of bending rotor, which is very common symptom of rotor rubbing with a part of stator. One way to detect bending rotor is monitoring of phasor of first harmonics (1X)signal component. Other symptoms of partial rub are subsynchronous spectral components, which arises from rotor periodic motion during rub. In this paper, the method of cumulative full spectrum, based on cepstral liftering and subsequent cumulation of full spectrum is introduced. This method is suitable for offline and also online detection of partial rub.
Název v anglickém jazyce
A Novel Method for Partial Rub Detection Based on Cumulation of Liftered Full Spectrum
Popis výsledku anglicky
Contemporary trend in design of turbomachinery leads to increase of efficiency through reducing the seal clearances. Tight rotor-to-seal clearance may lead to undesirable contact between rotating and stationary part of the machine, called simply rubbingor rub. The methods, standardly used for rub detection, are mainly based on observation of bending rotor, which is very common symptom of rotor rubbing with a part of stator. One way to detect bending rotor is monitoring of phasor of first harmonics (1X)signal component. Other symptoms of partial rub are subsynchronous spectral components, which arises from rotor periodic motion during rub. In this paper, the method of cumulative full spectrum, based on cepstral liftering and subsequent cumulation of full spectrum is introduced. This method is suitable for offline and also online detection of partial rub.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Communications, Circuits and Educational Technologies
ISBN
978-1-61804-231-6
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
72-79
Název nakladatele
Europment
Místo vydání
Sofia, Bulgaria
Místo konání akce
Praha
Datum konání akce
2. 4. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—