Treatment with fixed appliances and clear plastic appliances. Evaluation of results
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23520%2F19%3A43955261" target="_blank" >RIV/49777513:23520/19:43955261 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.orthodont-cz.cz/modul/casopis_clanek/soubory/Clanek-Ortodoncie-02-2019-02.pdf" target="_blank" >https://www.orthodont-cz.cz/modul/casopis_clanek/soubory/Clanek-Ortodoncie-02-2019-02.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Treatment with fixed appliances and clear plastic appliances. Evaluation of results
Popis výsledku v původním jazyce
Aims: The retrospective study assessed outcomes of orthodontic treatment using fixed appliance and clear plastic aligner with PAR index, and compared effectiveness of the therapy with TEI (treatment efficiency index). Another aim was to compare the number of occlusal contacts and assess root parallelism in orthopantomogram. Material: The sample included 80 patients - 40 treated with fixed appliance, 40 with Invisalign. Method: PAR (Peer Assessment Rating) index was measured in all patients prior and after treatment in digital dental casts; the number of occlusal contacts was measured in occlusogram. Root parallelism was measured in OPG made prior and after the treatment. Conclusion: Results for both groups were acceptable. However, better quality results were achieved in the group treated with conventional fixed appliances. The length of treatment was shorter in the group treated with Invisalign. The number of occlusal contacts after the treatment was higher in patients treated with fixed appliance. Better root parallelism was found in patients with fixed appliance, the only exception being lower anterior segment where the results were similar in both groups.
Název v anglickém jazyce
Treatment with fixed appliances and clear plastic appliances. Evaluation of results
Popis výsledku anglicky
Aims: The retrospective study assessed outcomes of orthodontic treatment using fixed appliance and clear plastic aligner with PAR index, and compared effectiveness of the therapy with TEI (treatment efficiency index). Another aim was to compare the number of occlusal contacts and assess root parallelism in orthopantomogram. Material: The sample included 80 patients - 40 treated with fixed appliance, 40 with Invisalign. Method: PAR (Peer Assessment Rating) index was measured in all patients prior and after treatment in digital dental casts; the number of occlusal contacts was measured in occlusogram. Root parallelism was measured in OPG made prior and after the treatment. Conclusion: Results for both groups were acceptable. However, better quality results were achieved in the group treated with conventional fixed appliances. The length of treatment was shorter in the group treated with Invisalign. The number of occlusal contacts after the treatment was higher in patients treated with fixed appliance. Better root parallelism was found in patients with fixed appliance, the only exception being lower anterior segment where the results were similar in both groups.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
30208 - Dentistry, oral surgery and medicine
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ortodoncie
ISSN
1210-4272
e-ISSN
—
Svazek periodika
28
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
13
Strana od-do
89-101
Kód UT WoS článku
—