Numerical simulations of droplet evaporation in a SCR system submodel with hot air flow
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23640%2F19%3A43958170" target="_blank" >RIV/49777513:23640/19:43958170 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1063/1.5138628" target="_blank" >http://dx.doi.org/10.1063/1.5138628</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5138628" target="_blank" >10.1063/1.5138628</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Numerical simulations of droplet evaporation in a SCR system submodel with hot air flow
Popis výsledku v původním jazyce
The paper focuses on the numerical simulation of liquid droplet evaporation in a hot air flow in a submodel which is created in conformity with a real life application in a Selective Catalytic Reduction (SCR) system. Simulations of droplet evaporation processes in the SCR system are complex, so it was necessary to create a submodel to verify the stability of the evaporation model in ANSYS Fluent CFD code. Evaporation is a complex process which happens even below the evaporation point, but once the temperature of the liquid reaches this point the process becomes a lot faster. Simulations are made with AdBlue® which is a liquid made of urine and water. The simulation results are compared with available experiments and show that the applied method for droplet evaporation is suitable. These successful results mean that the next step is the application of this model to a complete SCR system.
Název v anglickém jazyce
Numerical simulations of droplet evaporation in a SCR system submodel with hot air flow
Popis výsledku anglicky
The paper focuses on the numerical simulation of liquid droplet evaporation in a hot air flow in a submodel which is created in conformity with a real life application in a Selective Catalytic Reduction (SCR) system. Simulations of droplet evaporation processes in the SCR system are complex, so it was necessary to create a submodel to verify the stability of the evaporation model in ANSYS Fluent CFD code. Evaporation is a complex process which happens even below the evaporation point, but once the temperature of the liquid reaches this point the process becomes a lot faster. Simulations are made with AdBlue® which is a liquid made of urine and water. The simulation results are compared with available experiments and show that the applied method for droplet evaporation is suitable. These successful results mean that the next step is the application of this model to a complete SCR system.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace<br>O - Projekt operacniho programu
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
AIP Conference Proceedings 2189
ISBN
978-0-7354-1936-0
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
"NESTRÁNKOVÁNO"
Název nakladatele
Západočeská univerzita v Plzni, Katedra energetických strojů a zařízení
Místo vydání
Spojené státy americké
Místo konání akce
Plzeň
Datum konání akce
11. 6. 2019
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—