Dynamika oxidačně-redukčního potenciálu v poli kořenové čistírny odpadních vod s podpovrchovým horizontálním tokem: denní, sezónní a prostorová variabilita
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12310%2F08%3A00009811" target="_blank" >RIV/60076658:12310/08:00009811 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Redox potential dynamics in a horizontal subsurface flow constructed wetland for wastewater treatment: Diel, seasonal and spatial fluctuations
Popis výsledku v původním jazyce
Redox potential was measured in a treatment bed of a constructed wetland (CW) with subsurface horizontal flow used for municipal wastewater treatment. CW was situated in the Czech Republic, designed for 150 person equivalents; it was planted with Phragmites australis and put into operation in 2001. The system was very efficient in removing organic pollution (BOD5 82% and COD 74.0%), nitrogen (62.6%), phosphorus (75.4%) and suspended solids (52%). Redox potential (EH) was measured in two depths (0.2 and0.5 m) of the treatment bed at regular distances from inflow using platinum electrodes, continuously, every 15 min during a more-than-2-year period (27 months) from 2002 to 2004. EH ranged from -400 to +800mV. The fluctuations were the most intense in the upper layer (0.2 m) at the furthest distance from inflow (13 m) and EH changed within very short time periods (hours) by several hundred millivolts. Among the factors affecting EH concentrations of pollutants, pore water temperature and
Název v anglickém jazyce
Redox potential dynamics in a horizontal subsurface flow constructed wetland for wastewater treatment: Diel, seasonal and spatial fluctuations
Popis výsledku anglicky
Redox potential was measured in a treatment bed of a constructed wetland (CW) with subsurface horizontal flow used for municipal wastewater treatment. CW was situated in the Czech Republic, designed for 150 person equivalents; it was planted with Phragmites australis and put into operation in 2001. The system was very efficient in removing organic pollution (BOD5 82% and COD 74.0%), nitrogen (62.6%), phosphorus (75.4%) and suspended solids (52%). Redox potential (EH) was measured in two depths (0.2 and0.5 m) of the treatment bed at regular distances from inflow using platinum electrodes, continuously, every 15 min during a more-than-2-year period (27 months) from 2002 to 2004. EH ranged from -400 to +800mV. The fluctuations were the most intense in the upper layer (0.2 m) at the furthest distance from inflow (13 m) and EH changed within very short time periods (hours) by several hundred millivolts. Among the factors affecting EH concentrations of pollutants, pore water temperature and
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ecological Engineering
ISSN
0925-8574
e-ISSN
—
Svazek periodika
34
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
000261456900004
EID výsledku v databázi Scopus
—