Dynamika oxidačně redukčního potenciálu v kořenové čistírně s horizontálním podpovrchovým tokem: Denní, sezónní a prostorové kolísání
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67179843%3A_____%2F08%3A00320210" target="_blank" >RIV/67179843:_____/08:00320210 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Redox potential dynamics in a horizontal subsurface flow constructed wetland for wastewater treatment: Diel, seasonal ans spatial fluctuations
Popis výsledku v původním jazyce
Redox potential was measured in a treatment bed of a constructed wetland (CW) with subsurface horizontal flow used for municipal wastewater treatment. Redox potential (EH) was measured in two depths (0.2 and 0.5 m) of the treatment bed at regular distances from inflow using platinum electrodes, continuously, every 15 min during a more-than-2-year period (27 months) from 2002 to 2004. EH ranged from ?400 to +800mV. The fluctuations were the most intense in the upper layer (0.2 m) at the furthest distancefrom inflow (13 m) and EH changed within very short time periods (hours) by several hundred millivolts. Among the factors affecting EH concentrations of pollutants, pore water temperature and water flow rate were determined.
Název v anglickém jazyce
Redox potential dynamics in a horizontal subsurface flow constructed wetland for wastewater treatment: Diel, seasonal ans spatial fluctuations
Popis výsledku anglicky
Redox potential was measured in a treatment bed of a constructed wetland (CW) with subsurface horizontal flow used for municipal wastewater treatment. Redox potential (EH) was measured in two depths (0.2 and 0.5 m) of the treatment bed at regular distances from inflow using platinum electrodes, continuously, every 15 min during a more-than-2-year period (27 months) from 2002 to 2004. EH ranged from ?400 to +800mV. The fluctuations were the most intense in the upper layer (0.2 m) at the furthest distancefrom inflow (13 m) and EH changed within very short time periods (hours) by several hundred millivolts. Among the factors affecting EH concentrations of pollutants, pore water temperature and water flow rate were determined.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ecological Engineering
ISSN
0925-8574
e-ISSN
—
Svazek periodika
34
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
—
Kód UT WoS článku
—