Comparison of the quantitative performance of a Q-Exactive high-resolution mass spectrometer with that of a triple quadrupole tandem mass spectrometer for the analysis of illicit drugs in wastewater

Identifikátory výsledku

  • Kód výsledku v IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12520%2F13%3A43885226" target="_blank" >RIV/60076658:12520/13:43885226 - isvavai.cz</a>

  • Výsledek na webu

    <a href="http://onlinelibrary.wiley.com/doi/10.1002/rcm.6628/abstract" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/rcm.6628/abstract</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/rcm.6628" target="_blank" >10.1002/rcm.6628</a>

Alternativní jazyky

  • Jazyk výsledku

    angličtina

  • Název v původním jazyce

    Comparison of the quantitative performance of a Q-Exactive high-resolution mass spectrometer with that of a triple quadrupole tandem mass spectrometer for the analysis of illicit drugs in wastewater

  • Popis výsledku v původním jazyce

    RATIONALE Analysis of drugs in wastewater is gaining more interest, as new approaches to estimate drug consumption from the amount of drug residues in wastewater have been proposed. The aim of this study was to compare the quantitative performance of high-resolution mass spectrometry with that of triple quadrupole mass spectrometry. METHODS A Q-Exactive mass spectrometer was operated in full scan (HRFS) (70 000 FWHM) and product scan (HRPS) (17 500 FWHM) modes. The first and third quadrupoles of the QqQMS/MS instrument were operated at 0.7 FWHM. A mass-extracted window of 5ppm around the theoretical m/z of each analyte was used to construct chromatograms. An HESI-II ion source was used for the ionization of target compounds. In-line-SPE-LC configuration was used for the extraction and separation of target analytes. RESULTS All three methods showed good linearity and repeatability. High-resolution detection of product ions exhibited better sensitivity and selectivity for some compounds

  • Název v anglickém jazyce

    Comparison of the quantitative performance of a Q-Exactive high-resolution mass spectrometer with that of a triple quadrupole tandem mass spectrometer for the analysis of illicit drugs in wastewater

  • Popis výsledku anglicky

    RATIONALE Analysis of drugs in wastewater is gaining more interest, as new approaches to estimate drug consumption from the amount of drug residues in wastewater have been proposed. The aim of this study was to compare the quantitative performance of high-resolution mass spectrometry with that of triple quadrupole mass spectrometry. METHODS A Q-Exactive mass spectrometer was operated in full scan (HRFS) (70 000 FWHM) and product scan (HRPS) (17 500 FWHM) modes. The first and third quadrupoles of the QqQMS/MS instrument were operated at 0.7 FWHM. A mass-extracted window of 5ppm around the theoretical m/z of each analyte was used to construct chromatograms. An HESI-II ion source was used for the ionization of target compounds. In-line-SPE-LC configuration was used for the extraction and separation of target analytes. RESULTS All three methods showed good linearity and repeatability. High-resolution detection of product ions exhibited better sensitivity and selectivity for some compounds

Klasifikace

  • Druh

    J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)

  • CEP obor

    DJ - Znečištění a kontrola vody

  • OECD FORD obor

Návaznosti výsledku

  • Projekt

    <a href="/cs/project/ED2.1.00%2F01.0024" target="_blank" >ED2.1.00/01.0024: Jihočeské výzkumné centrum akvakultury a biodiverzity hydrocenóz</a><br>

  • Návaznosti

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Ostatní

  • Rok uplatnění

    2013

  • Kód důvěrnosti údajů

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Údaje specifické pro druh výsledku

  • Název periodika

    RAPID COMMUNICATIONS IN MASS SPECTROMETRY

  • ISSN

    0951-4198

  • e-ISSN

  • Svazek periodika

    27

  • Číslo periodika v rámci svazku

    15

  • Stát vydavatele periodika

    US - Spojené státy americké

  • Počet stran výsledku

    12

  • Strana od-do

    1751-1762

  • Kód UT WoS článku

    000321203700009

  • EID výsledku v databázi Scopus