Spectroscopic Approach to Correction and Visualisation of Bright-Field Light Transmission Microscopy Biological Data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12520%2F21%3A43902708" target="_blank" >RIV/60076658:12520/21:43902708 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11320/21:10436149
Výsledek na webu
<a href="https://doi.org/10.3390/photonics8080333" target="_blank" >https://doi.org/10.3390/photonics8080333</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/photonics8080333" target="_blank" >10.3390/photonics8080333</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spectroscopic Approach to Correction and Visualisation of Bright-Field Light Transmission Microscopy Biological Data
Popis výsledku v původním jazyce
The most realistic information about a transparent sample such as a live cell can be obtained using bright-field light microscopy. Under high-intensity pulsing LED illumination, we captured a primary 12-bit-per-channel (bpc) response from an observed sample using a bright-field microscope equipped with a high-resolution (4872 x 3248) image sensor. In order to suppress data distortions originating from the light interactions with elements in the optical path, poor sensor reproduction (geometrical defects of the camera sensor and some peculiarities of sensor sensitivity), we propose a spectroscopic approach for the correction of these uncompressed 12 bpc data by simultaneous calibration of all parts of the experimental arrangement. Moreover, the final intensities of the corrected images are proportional to the photon fluxes detected by a camera sensor. It can be visualized in 8 bpc intensity depth after the Least Information Loss compression.
Název v anglickém jazyce
Spectroscopic Approach to Correction and Visualisation of Bright-Field Light Transmission Microscopy Biological Data
Popis výsledku anglicky
The most realistic information about a transparent sample such as a live cell can be obtained using bright-field light microscopy. Under high-intensity pulsing LED illumination, we captured a primary 12-bit-per-channel (bpc) response from an observed sample using a bright-field microscope equipped with a high-resolution (4872 x 3248) image sensor. In order to suppress data distortions originating from the light interactions with elements in the optical path, poor sensor reproduction (geometrical defects of the camera sensor and some peculiarities of sensor sensitivity), we propose a spectroscopic approach for the correction of these uncompressed 12 bpc data by simultaneous calibration of all parts of the experimental arrangement. Moreover, the final intensities of the corrected images are proportional to the photon fluxes detected by a camera sensor. It can be visualized in 8 bpc intensity depth after the Least Information Loss compression.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2018099" target="_blank" >LM2018099: Jihočeské výzkumné centrum akvakultury a biodiverzity hydrocenóz</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Photonics
ISSN
2304-6732
e-ISSN
2304-6732
Svazek periodika
8
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
18
Strana od-do
—
Kód UT WoS článku
000690188000001
EID výsledku v databázi Scopus
2-s2.0-85113770395