Evaluation of targeted and high-resolution mass spectrometry methods for environmental monitoring of pharmaceuticals
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12520%2F25%3A43910055" target="_blank" >RIV/60076658:12520/25:43910055 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.mex.2025.103666" target="_blank" >https://doi.org/10.1016/j.mex.2025.103666</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.mex.2025.103666" target="_blank" >10.1016/j.mex.2025.103666</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of targeted and high-resolution mass spectrometry methods for environmental monitoring of pharmaceuticals
Popis výsledku v původním jazyce
This study presents a comparison of three mass spectrometry-based analytical approaches-targeted tandem mass spectrometry (MS/MS), high-resolution full scan (HRFS), and data-independent acquisition (DIA)-for the quantification and screening of 74 pharmaceuticals across four environmental water matrices: tap water, river water, and influent and effluent wastewater. The methods were validated in terms of limits of quantification (LOQ), trueness, precision, and matrix effects. MS/MS exhibited the best overall performance, achieving the lowest LOQs (median 0.54 ng/L), highest trueness (median 101 %), and minimal matrix effects, confirming its suitability for routine regulatory monitoring. HRFS and DIA, while showing higher LOQs and variability, provided broader screening capabilities with acceptable trueness for 63 % and 81 % of compounds, respectively, and enabled retrospective data analysis. The methods were applied to real samples from the Zivn & yacute; Stream in the Czech Republic to determine pharmaceutical contamination downstream of a wastewater treatment plant (WWTP).
Název v anglickém jazyce
Evaluation of targeted and high-resolution mass spectrometry methods for environmental monitoring of pharmaceuticals
Popis výsledku anglicky
This study presents a comparison of three mass spectrometry-based analytical approaches-targeted tandem mass spectrometry (MS/MS), high-resolution full scan (HRFS), and data-independent acquisition (DIA)-for the quantification and screening of 74 pharmaceuticals across four environmental water matrices: tap water, river water, and influent and effluent wastewater. The methods were validated in terms of limits of quantification (LOQ), trueness, precision, and matrix effects. MS/MS exhibited the best overall performance, achieving the lowest LOQs (median 0.54 ng/L), highest trueness (median 101 %), and minimal matrix effects, confirming its suitability for routine regulatory monitoring. HRFS and DIA, while showing higher LOQs and variability, provided broader screening capabilities with acceptable trueness for 63 % and 81 % of compounds, respectively, and enabled retrospective data analysis. The methods were applied to real samples from the Zivn & yacute; Stream in the Czech Republic to determine pharmaceutical contamination downstream of a wastewater treatment plant (WWTP).
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA22-03754S" target="_blank" >GA22-03754S: Od mozku ke spermiím: jak mohou psychoaktivní polutanty ovlivnit funkci spermií ryb.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
MethodsX
ISSN
—
e-ISSN
2215-0161
Svazek periodika
15
Číslo periodika v rámci svazku
neuvedeno
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
10
Strana od-do
nestránkováno
Kód UT WoS článku
001593020000002
EID výsledku v databázi Scopus
2-s2.0-105018093958