NDT vodivých látek pomocí elektro-ultrazvukové spektroskopie
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F08%3A%230001776" target="_blank" >RIV/60162694:G43__/08:#0001776 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
NDT of Conducting Solids by Electro-Ultrasonic Spectroscopy
Popis výsledku v původním jazyce
The paper presents new NDT method of conducting solids. Tested sample is excited by harmonic electrical and ultrasonic signals with different frequencies. On the defect caused non linearity new harmonic signal is created with frequency given by subtraction of exciting frequencies fE and fU. It was found that the amplitude of the intermodulation component Ui is linear function of electrical excitation and quadratic function of ultrasonic excitation. High sensitivity of this method follows from the fact that the signal giving information on tested sample quality has frequency different from exciting signals. The signal to noise ratio and high sensitivity for NDT analyses is based on the application of special electrical filters. Experimental verificationof this method was performed on the samples of aluminum and dural plates and on the thick conducting films, both without and with cracks prepared artificially.
Název v anglickém jazyce
NDT of Conducting Solids by Electro-Ultrasonic Spectroscopy
Popis výsledku anglicky
The paper presents new NDT method of conducting solids. Tested sample is excited by harmonic electrical and ultrasonic signals with different frequencies. On the defect caused non linearity new harmonic signal is created with frequency given by subtraction of exciting frequencies fE and fU. It was found that the amplitude of the intermodulation component Ui is linear function of electrical excitation and quadratic function of ultrasonic excitation. High sensitivity of this method follows from the fact that the signal giving information on tested sample quality has frequency different from exciting signals. The signal to noise ratio and high sensitivity for NDT analyses is based on the application of special electrical filters. Experimental verificationof this method was performed on the samples of aluminum and dural plates and on the thick conducting films, both without and with cracks prepared artificially.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Symposium 18th ISNA 2008
ISBN
978-0-7354-0544-8
ISSN
0094-243X
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
American Institute of Physic