Vylepšení poměru signal šum u elektro-ultrazvukové spektroskopie
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F08%3APU78576" target="_blank" >RIV/00216305:26220/08:PU78576 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improved Signal to Noise Ratio of Electro-ultrasonic Spectroscopy
Popis výsledku v původním jazyce
The paper presents signal to noise consideration of a new NDT method. Tested sample is excited by electrical and ultrasonic signals with different frequencies. On the defect new harmonic signal is created with frequency given by subtraction of exciting frequencies fE and fU. High sensitivity of this method follows from the fact that the signal giving information on tested sample quality has frequency different from exciting signals. The signal to noise ratio and high sensitivity for NDT analyses is based on the application of special electrical filters. The theoretical sensitivity of this method and its limitation by parasitic effects is analyzed. Therefore the new variants of circuitry are designed and used for experimental verifying. First of all theequivalent dynamic range and final sensitivity is improved using linear filters to reduce the level of exciting signals in the amplifier input and by noise in exciting electrical signal reducing. The usability of this principle and possi
Název v anglickém jazyce
Improved Signal to Noise Ratio of Electro-ultrasonic Spectroscopy
Popis výsledku anglicky
The paper presents signal to noise consideration of a new NDT method. Tested sample is excited by electrical and ultrasonic signals with different frequencies. On the defect new harmonic signal is created with frequency given by subtraction of exciting frequencies fE and fU. High sensitivity of this method follows from the fact that the signal giving information on tested sample quality has frequency different from exciting signals. The signal to noise ratio and high sensitivity for NDT analyses is based on the application of special electrical filters. The theoretical sensitivity of this method and its limitation by parasitic effects is analyzed. Therefore the new variants of circuitry are designed and used for experimental verifying. First of all theequivalent dynamic range and final sensitivity is improved using linear filters to reduce the level of exciting signals in the amplifier input and by noise in exciting electrical signal reducing. The usability of this principle and possi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ElectroScope - http://www.electroscope.zcu.cz
ISSN
1802-4564
e-ISSN
—
Svazek periodika
2008
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—