The New High Sensitive Variant of Nonlinear Ultrasound Spectroscopy for Nondestructive Testing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F09%3A%230003142" target="_blank" >RIV/60162694:G43__/09:#0003142 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G43__/10:00445805
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The New High Sensitive Variant of Nonlinear Ultrasound Spectroscopy for Nondestructive Testing
Popis výsledku v původním jazyce
This paper presents comparison of two basic NDT methods used nonlinear ultrasound spectroscopy and it asks new possibilities for rising of sensitivity. The second part discusses possibility of using of the burst-wave exciting mode for these methods. Thenew variant of mixing method is derived, where such exciting frequencies are used, that result signal with difference frequency has a relatively high frequency and a shorter period then the exciting signal. On the other hand, the frequency difference between this result component and exciting signal is sufficient for using of LC linear filters with sufficient attenuation of exciting signals.
Název v anglickém jazyce
The New High Sensitive Variant of Nonlinear Ultrasound Spectroscopy for Nondestructive Testing
Popis výsledku anglicky
This paper presents comparison of two basic NDT methods used nonlinear ultrasound spectroscopy and it asks new possibilities for rising of sensitivity. The second part discusses possibility of using of the burst-wave exciting mode for these methods. Thenew variant of mixing method is derived, where such exciting frequencies are used, that result signal with difference frequency has a relatively high frequency and a shorter period then the exciting signal. On the other hand, the frequency difference between this result component and exciting signal is sufficient for using of LC linear filters with sufficient attenuation of exciting signals.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
AIMT - Advances in Military Technology
ISSN
1802-2308
e-ISSN
—
Svazek periodika
4
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
—