Příspěvek k řešení teplotního napětí ve válcové stěně pomocného raketového motoru
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG43__%2F08%3A%230001832" target="_blank" >RIV/60162694:G43__/08:#0001832 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Contribution to the Solution of thermal Stress in Cylindrical Wall of the Solid Propellant Booster
Popis výsledku v původním jazyce
The article deals with the thermal load of the solid propellant booster combustion chamber. In contribution the case of thermal stress of the cylindrical wall is analysed when the solid propellant booster has the short time of action. Thermal stress is aconsequence of the solid propellant booster charge burning. For this analyzes the thermal load is estimated from an experiment. The stresses are assessed in the meridional and hoop directions. Cylindrical part of the combustion chamber is closed on oneend by the rigid plate and is considered as a shell construction. The pressure and thermal load are axisymmetrical. The new in this paper is evaluation of the thermo camera usage for the temperature fields estimation on the combustion chamber construction during experiments.
Název v anglickém jazyce
Contribution to the Solution of thermal Stress in Cylindrical Wall of the Solid Propellant Booster
Popis výsledku anglicky
The article deals with the thermal load of the solid propellant booster combustion chamber. In contribution the case of thermal stress of the cylindrical wall is analysed when the solid propellant booster has the short time of action. Thermal stress is aconsequence of the solid propellant booster charge burning. For this analyzes the thermal load is estimated from an experiment. The stresses are assessed in the meridional and hoop directions. Cylindrical part of the combustion chamber is closed on oneend by the rigid plate and is considered as a shell construction. The pressure and thermal load are axisymmetrical. The new in this paper is evaluation of the thermo camera usage for the temperature fields estimation on the combustion chamber construction during experiments.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JT - Pohon, motory a paliva
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Mechanica Slovaca
ISSN
1335-2393
e-ISSN
—
Svazek periodika
2008
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
SK - Slovenská republika
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—