Determination of fumonisins in milled corn grains using HPLC/MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F10%3A00002332" target="_blank" >RIV/60162694:G44__/10:00002332 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/25328859:_____/10:#0000527 RIV/44555601:13440/10:00005559
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of fumonisins in milled corn grains using HPLC/MS
Popis výsledku v původním jazyce
A new method for determination of fumonisins in corn samples was developed and validated. The mycotoxins were extracted by a mixture of methanol-acetonitrile-water (1:1:2, v/v/v) and determined on a liquid chromatograph with mass spectrometric detection.The separation was performed on Zorbax XDB-C(18) column (150 x 4.6 mm; 5 microm) with a Metaguard ODS-2 precolumn (30 x 4.6 mm; 5 mum) using gradient elution with mobile phase consisting of acetonitrile and 5 mmol/L ammonium acetate (adjusted by aceticacid to pH 3.0). For detection of (M+H(+)) ions, a quadrupole mass spectrometer in single ion monitoring mode was applied. Developed method showed very good linearity in a tested range of concentration. Detection limit is 62.0 microg FB(1)/kg and 58.5 microg FB(2)/kg of maize grains. Because the detection limits lie under the maximum permitted EU levels, the method is suitable for determination of fumonisins in milled corn grains.
Název v anglickém jazyce
Determination of fumonisins in milled corn grains using HPLC/MS
Popis výsledku anglicky
A new method for determination of fumonisins in corn samples was developed and validated. The mycotoxins were extracted by a mixture of methanol-acetonitrile-water (1:1:2, v/v/v) and determined on a liquid chromatograph with mass spectrometric detection.The separation was performed on Zorbax XDB-C(18) column (150 x 4.6 mm; 5 microm) with a Metaguard ODS-2 precolumn (30 x 4.6 mm; 5 mum) using gradient elution with mobile phase consisting of acetonitrile and 5 mmol/L ammonium acetate (adjusted by aceticacid to pH 3.0). For detection of (M+H(+)) ions, a quadrupole mass spectrometer in single ion monitoring mode was applied. Developed method showed very good linearity in a tested range of concentration. Detection limit is 62.0 microg FB(1)/kg and 58.5 microg FB(2)/kg of maize grains. Because the detection limits lie under the maximum permitted EU levels, the method is suitable for determination of fumonisins in milled corn grains.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatographic Science
ISSN
0021-9665
e-ISSN
—
Svazek periodika
48
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
—
Kód UT WoS článku
000281047400012
EID výsledku v databázi Scopus
—