An assay of creatine in human serum using an HPLC with UV detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216275%3A25310%2F13%3A39896728" target="_blank" >RIV/00216275:25310/13:39896728 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An assay of creatine in human serum using an HPLC with UV detection
Popis výsledku v původním jazyce
An ion-exchange high-performance liquid chromatography with ultraviolet detection for the determination of creatine in human serum has been developed. The human serum was deproteinized with perchloric acid. For the separation, a cation-exchange column LC-SCX, 250 mm x 4.6 mm, 5 um, was used. The mixture of ethanol and 10mmol l-1 ammonium acetate (15:85, v/v), pH 4.00+/-0.05 was used as a mobile phase. The analytical performance of this method is satisfactory: the intra-assay and inter-assay coefficientsof variation were below 10%. Quantitative recoveries of spiked serum samples were between 97.1% and 103.5%. The calibration curve was linear in the whole range tested. The limit of quantification was 2 umol l-1. The preliminary reference ranges of serumcreatine in a group of blood donors are 17-89 umol l-1 for women and 21-97 umol l-1 for men.
Název v anglickém jazyce
An assay of creatine in human serum using an HPLC with UV detection
Popis výsledku anglicky
An ion-exchange high-performance liquid chromatography with ultraviolet detection for the determination of creatine in human serum has been developed. The human serum was deproteinized with perchloric acid. For the separation, a cation-exchange column LC-SCX, 250 mm x 4.6 mm, 5 um, was used. The mixture of ethanol and 10mmol l-1 ammonium acetate (15:85, v/v), pH 4.00+/-0.05 was used as a mobile phase. The analytical performance of this method is satisfactory: the intra-assay and inter-assay coefficientsof variation were below 10%. Quantitative recoveries of spiked serum samples were between 97.1% and 103.5%. The calibration curve was linear in the whole range tested. The limit of quantification was 2 umol l-1. The preliminary reference ranges of serumcreatine in a group of blood donors are 17-89 umol l-1 for women and 21-97 umol l-1 for men.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scientific Papers of the University of Pardubice, Series A, Faculty of Chemical Technology
ISSN
1211-5541
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
prosinec
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
10
Strana od-do
39-48
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—