Piezoelectric Immunosensor for Tissue Transglutaminase Antibodies Determination for Celiac Disease Diagnostic and Comparison with ELISA Method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F20%3A00555984" target="_blank" >RIV/60162694:G44__/20:00555984 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.electrochemsci.org/abstracts/vol15/150605154.pdf" target="_blank" >http://www.electrochemsci.org/abstracts/vol15/150605154.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.20964/2020.06.36" target="_blank" >10.20964/2020.06.36</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Piezoelectric Immunosensor for Tissue Transglutaminase Antibodies Determination for Celiac Disease Diagnostic and Comparison with ELISA Method
Popis výsledku v původním jazyce
Celiac disease (CD) is a hereditary disease characterized by occurrence of IgA class antibodies against tissue transglutaminase (anti-tTG) in serum. In this work, we compared standard Enzyme-Linked Immunosorbent Assay (ELISA) with a quartz crystal microbalance (QCM) measuring system for determination of anti-tTG. The new immunosensor is based on immobilized tTG in an open conformation (open-tTG) and optimized for assay of IgA anti-tTG with limit of detection 13.3 RU/ml and good specificity and stability over time. Testing serum samples of patients suffering CD showed suitability of the prepared immunosensor for practical performance. Compare to ELISA requiring skilled personnel and expensive equipment, the newly constructed measuring system for measurement of QCM sensor is cheap, easy to prepare and does not require any special skill thus it can be introduced into any laboratory or general practitioner office.
Název v anglickém jazyce
Piezoelectric Immunosensor for Tissue Transglutaminase Antibodies Determination for Celiac Disease Diagnostic and Comparison with ELISA Method
Popis výsledku anglicky
Celiac disease (CD) is a hereditary disease characterized by occurrence of IgA class antibodies against tissue transglutaminase (anti-tTG) in serum. In this work, we compared standard Enzyme-Linked Immunosorbent Assay (ELISA) with a quartz crystal microbalance (QCM) measuring system for determination of anti-tTG. The new immunosensor is based on immobilized tTG in an open conformation (open-tTG) and optimized for assay of IgA anti-tTG with limit of detection 13.3 RU/ml and good specificity and stability over time. Testing serum samples of patients suffering CD showed suitability of the prepared immunosensor for practical performance. Compare to ELISA requiring skilled personnel and expensive equipment, the newly constructed measuring system for measurement of QCM sensor is cheap, easy to prepare and does not require any special skill thus it can be introduced into any laboratory or general practitioner office.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
<a href="/cs/project/TJ01000478" target="_blank" >TJ01000478: Konstrukce senzoru pro kvantitativní stanovení protilátek proti tkáňové transglutaminase pro diagnostiku celiakie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
—
Svazek periodika
15
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
RS - Srbská republika
Počet stran výsledku
12
Strana od-do
5154-5165
Kód UT WoS článku
000551697600027
EID výsledku v databázi Scopus
2-s2.0-85086838446