Glycated Hemoglobin and Methods for Its Point of Care Testing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F21%3A00556884" target="_blank" >RIV/60162694:G44__/21:00556884 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/2079-6374/11/3/70" target="_blank" >https://www.mdpi.com/2079-6374/11/3/70</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/bios11030070" target="_blank" >10.3390/bios11030070</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Glycated Hemoglobin and Methods for Its Point of Care Testing
Popis výsledku v původním jazyce
Glycated hemoglobin (HbA(1c)) is a product of the spontaneous reaction between hemoglobin and elevated glucose levels in the blood. It is included among the so-called advanced glycation end products, of which is the most important for the clinical diagnosis of diabetes mellitus, and it can serve as an alternative to glycemia measurement. Compared to the diagnosis of diabetes mellitus by glycemia, the HbA(1c) level is less influenced by a short-term problem with diabetes compensation. Mass spectroscopy and chromatographic techniques are among the standard methods of HbA(1c) level measurement. Compared to glycemia measurement, there is lack of simple methods for diabetes mellitus diagnosis by means of the HbA(1c) assay using a point-of-care test. This review article is focused on the surveying of facts about HbA(1c) and its importance in diabetes mellitus diagnosis, and surveying standard methods and new methods suitable for the HbA(1c) assay under point-of-care conditions. Various bioassays and biosensors are mentioned and their specifications are discussed.
Název v anglickém jazyce
Glycated Hemoglobin and Methods for Its Point of Care Testing
Popis výsledku anglicky
Glycated hemoglobin (HbA(1c)) is a product of the spontaneous reaction between hemoglobin and elevated glucose levels in the blood. It is included among the so-called advanced glycation end products, of which is the most important for the clinical diagnosis of diabetes mellitus, and it can serve as an alternative to glycemia measurement. Compared to the diagnosis of diabetes mellitus by glycemia, the HbA(1c) level is less influenced by a short-term problem with diabetes compensation. Mass spectroscopy and chromatographic techniques are among the standard methods of HbA(1c) level measurement. Compared to glycemia measurement, there is lack of simple methods for diabetes mellitus diagnosis by means of the HbA(1c) assay using a point-of-care test. This review article is focused on the surveying of facts about HbA(1c) and its importance in diabetes mellitus diagnosis, and surveying standard methods and new methods suitable for the HbA(1c) assay under point-of-care conditions. Various bioassays and biosensors are mentioned and their specifications are discussed.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biosensors-Basel
ISSN
2079-6374
e-ISSN
2079-6374
Svazek periodika
11
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
12
Strana od-do
70
Kód UT WoS článku
000633395200001
EID výsledku v databázi Scopus
2-s2.0-85103862731