Assessment of the Tourniquets Application Time, Effectiveness and Simplicity
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F21%3A00557004" target="_blank" >RIV/60162694:G44__/21:00557004 - isvavai.cz</a>
Výsledek na webu
<a href="https://mmsl.cz/corproof.php?tartkey=mms-000000-0173" target="_blank" >https://mmsl.cz/corproof.php?tartkey=mms-000000-0173</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.31482/mmsl.2021.013" target="_blank" >10.31482/mmsl.2021.013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of the Tourniquets Application Time, Effectiveness and Simplicity
Popis výsledku v původním jazyce
Damaged arteries bleeding can cause a life-threatening condition and it is one the main causes of death which can be prevented both on the battlefield and in the civilian environment. In case when severe external bleeding in a limb cannot be controlled by direct pressure a tourniquet should be used. Four different types of tourniquets were tested to determine which type of tourniquet is effective to be used in the Army of the Czech Republic. The C-A-T 7 tourniquet was best evaluated, followed by the CZ Tactical tourniquet, the C-A-T 6 and the SOFTT. A significant difference between C-A-T 7, CZ Tactical tourniquet and C-A-T 6 on one side and SOFTT one the other side and a significant difference between male and female correct tourniquet application was found out.
Název v anglickém jazyce
Assessment of the Tourniquets Application Time, Effectiveness and Simplicity
Popis výsledku anglicky
Damaged arteries bleeding can cause a life-threatening condition and it is one the main causes of death which can be prevented both on the battlefield and in the civilian environment. In case when severe external bleeding in a limb cannot be controlled by direct pressure a tourniquet should be used. Four different types of tourniquets were tested to determine which type of tourniquet is effective to be used in the Army of the Czech Republic. The C-A-T 7 tourniquet was best evaluated, followed by the CZ Tactical tourniquet, the C-A-T 6 and the SOFTT. A significant difference between C-A-T 7, CZ Tactical tourniquet and C-A-T 6 on one side and SOFTT one the other side and a significant difference between male and female correct tourniquet application was found out.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30221 - Critical care medicine and Emergency medicine
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Military Medical Science Letters
ISSN
0372-7025
e-ISSN
2571-113X
Svazek periodika
90
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
9
Strana od-do
137-145
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85114601036