Mitochondria in biodosimetry: flow cytometry assesment in vitro
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F23%3A00558274" target="_blank" >RIV/60162694:G44__/23:00558274 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/rpd/article-abstract/198/9-11/521/6673013?redirectedFrom=fulltext" target="_blank" >https://academic.oup.com/rpd/article-abstract/198/9-11/521/6673013?redirectedFrom=fulltext</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncac092" target="_blank" >10.1093/rpd/ncac092</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mitochondria in biodosimetry: flow cytometry assesment in vitro
Popis výsledku v původním jazyce
The JC-1 dye is widely used in apoptosis studies to monitor mitochondrial health. The probe was tested in vitro on two established cell lines and peripheral porcine blood lymphocytes after gamma irradiation (IR) to assess its potential in biodosimetric evaluation. In brief, we stained irradiated and non-irradiated cells with the JC-1 dye to determine the existing changes in mitochondrial membrane potential and monitor cell health through flow cytometry. The stage of injury in these cells was evaluated through an irradiated versus non-irradiated ratio (IVNIR), comparing the relative proportion of polarised cells containing red JC-1 aggregates. We observed a decreasing IVNIR as the radiation dose increased (i.e. 0.5; 1; 2; 4; 6; 8 and 10 Gy), performing the analysis at 4, 8 and 24 h after IR in all the tested cells. The results from the JC1-dye test showed that CD4 T lymphocytes were more sensitive to irradiation than other subpopulations.
Název v anglickém jazyce
Mitochondria in biodosimetry: flow cytometry assesment in vitro
Popis výsledku anglicky
The JC-1 dye is widely used in apoptosis studies to monitor mitochondrial health. The probe was tested in vitro on two established cell lines and peripheral porcine blood lymphocytes after gamma irradiation (IR) to assess its potential in biodosimetric evaluation. In brief, we stained irradiated and non-irradiated cells with the JC-1 dye to determine the existing changes in mitochondrial membrane potential and monitor cell health through flow cytometry. The stage of injury in these cells was evaluated through an irradiated versus non-irradiated ratio (IVNIR), comparing the relative proportion of polarised cells containing red JC-1 aggregates. We observed a decreasing IVNIR as the radiation dose increased (i.e. 0.5; 1; 2; 4; 6; 8 and 10 Gy), performing the analysis at 4, 8 and 24 h after IR in all the tested cells. The results from the JC1-dye test showed that CD4 T lymphocytes were more sensitive to irradiation than other subpopulations.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10511 - Environmental sciences (social aspects to be 5.7)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
1742-3406
Svazek periodika
198
Číslo periodika v rámci svazku
9-11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
521-526
Kód UT WoS článku
000844405700005
EID výsledku v databázi Scopus
2-s2.0-85137124613