Study of new luminophores for use in modern scintillation cocktails
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG45__%2F18%3A00535164" target="_blank" >RIV/60162694:G45__/18:00535164 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0022231318305507" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0022231318305507</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jlumin.2018.05.027" target="_blank" >10.1016/j.jlumin.2018.05.027</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of new luminophores for use in modern scintillation cocktails
Popis výsledku v původním jazyce
This paper deals with the study of 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline, 2,2',7,7'-tetrakis(N,N-diphenyl-amino)-9,9'-spirobifluorene, 2-(4-biphenylyl)-6-phenylbenzoxazole and 9,9'-bifluorenyl as possible replacements of the existing and most widely used luminophore (2.5-diphenyloxazole (PPO)) in contemporary scintillators. The study is focused on the determination of emission wavelength, concentration optimization, the influence of the wavelength shifters POPOP and bis-MSB. In addition, the response to alpha and beta radiation were measured, in particular, the pulse length index (PLI) was determined. Finally, yet importantly, the effect of emulsifiers on the shape of the spectrum and the solubility of the aqueous phase was tested. The results obtained were compared with the commercially available Aqualight scintillation cocktail.
Název v anglickém jazyce
Study of new luminophores for use in modern scintillation cocktails
Popis výsledku anglicky
This paper deals with the study of 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline, 2,2',7,7'-tetrakis(N,N-diphenyl-amino)-9,9'-spirobifluorene, 2-(4-biphenylyl)-6-phenylbenzoxazole and 9,9'-bifluorenyl as possible replacements of the existing and most widely used luminophore (2.5-diphenyloxazole (PPO)) in contemporary scintillators. The study is focused on the determination of emission wavelength, concentration optimization, the influence of the wavelength shifters POPOP and bis-MSB. In addition, the response to alpha and beta radiation were measured, in particular, the pulse length index (PLI) was determined. Finally, yet importantly, the effect of emulsifiers on the shape of the spectrum and the solubility of the aqueous phase was tested. The results obtained were compared with the commercially available Aqualight scintillation cocktail.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
50902 - Social sciences, interdisciplinary
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Luminescence
ISSN
0022-2313
e-ISSN
1872-7883
Svazek periodika
201
Číslo periodika v rámci svazku
September 2018
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
390-396
Kód UT WoS článku
000433882000054
EID výsledku v databázi Scopus
2-s2.0-85047186269