Performance comparison of experimental liquid scintillation cocktails
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG45__%2F18%3A00535547" target="_blank" >RIV/60162694:G45__/18:00535547 - isvavai.cz</a>
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s10967-018-6211-8" target="_blank" >https://link.springer.com/article/10.1007/s10967-018-6211-8</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10967-018-6211-8" target="_blank" >10.1007/s10967-018-6211-8</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Performance comparison of experimental liquid scintillation cocktails
Popis výsledku v původním jazyce
In this article the properties of four new luminophores, from the group of bifluorenes and other substances with multiple aromatic rings, were measured and studied for possible use in liquid scintillation, namely 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline, 2,2′,7,7′-tetrakis(N,N-diphenyl-amino)-9,9′-spirobifluorene, 2-(4-biphenylyl)-6-phenylbenzoxazole and 9,9′-bifluorenyl. The measurement was also done for the most commonly used luminophore (2,5-diphenyloxazole (PPO)). To improve counting efficiency the wavelength shifters were added to scintillation cocktail in particular POPOP and bis-MSB. The main effort was focused on the determination of sample counting efficiency of experimental cocktails using radionuclides Am-241, Sr-90 and H-3, especially for acidic, alkaline and neutral water solutions. The results were compared with the commercially used Aqualight scintillation cocktail.
Název v anglickém jazyce
Performance comparison of experimental liquid scintillation cocktails
Popis výsledku anglicky
In this article the properties of four new luminophores, from the group of bifluorenes and other substances with multiple aromatic rings, were measured and studied for possible use in liquid scintillation, namely 1-phenyl-3-(2,4,6-trimethyl-phenyl)-2-pyrazoline, 2,2′,7,7′-tetrakis(N,N-diphenyl-amino)-9,9′-spirobifluorene, 2-(4-biphenylyl)-6-phenylbenzoxazole and 9,9′-bifluorenyl. The measurement was also done for the most commonly used luminophore (2,5-diphenyloxazole (PPO)). To improve counting efficiency the wavelength shifters were added to scintillation cocktail in particular POPOP and bis-MSB. The main effort was focused on the determination of sample counting efficiency of experimental cocktails using radionuclides Am-241, Sr-90 and H-3, especially for acidic, alkaline and neutral water solutions. The results were compared with the commercially used Aqualight scintillation cocktail.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
50902 - Social sciences, interdisciplinary
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Radioanalytical and Nuclear Chemistry
ISSN
0236-5731
e-ISSN
1588-2780
Svazek periodika
318
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
11
Strana od-do
2235-2245
Kód UT WoS článku
000451746300079
EID výsledku v databázi Scopus
2-s2.0-85053919362