Liquid-liquid extraction of Am(III), Pu(IV), and U(VI) using malonamide and tributyl phosphate in room temperature ionic liquids as diluent
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG45__%2F25%3A00563889" target="_blank" >RIV/60162694:G45__/25:00563889 - isvavai.cz</a>
Výsledek na webu
<a href="https://doiserbia.nb.rs/Article.aspx?ID=1451-39942402138K" target="_blank" >https://doiserbia.nb.rs/Article.aspx?ID=1451-39942402138K</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.2298/NTRP2402138K" target="_blank" >10.2298/NTRP2402138K</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Liquid-liquid extraction of Am(III), Pu(IV), and U(VI) using malonamide and tributyl phosphate in room temperature ionic liquids as diluent
Popis výsledku v původním jazyce
The extraction behavior of americium, plutonium, and uranium from nitric or hydrochloric acidic medium by a solution of malonamide or tributyl phosphate in trioctylmethylammonium chloride (Aliquat 336) or trihexyl(tetradecyl)phosphonium chloride (Cyphos 101) ionic liquids were studied. The extraction percentage of these actinides was measured as a function of a concentration of nitric or hydrochloric acid and a set combination of a room temperature ionic liquid and an extractant. The pure room temperature ionic liquids could extract the plutonium and uranium to various degrees, with the combinations with extractants affecting the extraction percentages further. The 100 % extraction efficiency of plutonium was achieved across all concentrations of HCl with the combinations of Cyphos 101 and malonamide. 100% extraction efficiency of uranium was achieved by Cyphos 101 and malonamide from distilled water. Americium was not extracted by any combination under any conditions.
Název v anglickém jazyce
Liquid-liquid extraction of Am(III), Pu(IV), and U(VI) using malonamide and tributyl phosphate in room temperature ionic liquids as diluent
Popis výsledku anglicky
The extraction behavior of americium, plutonium, and uranium from nitric or hydrochloric acidic medium by a solution of malonamide or tributyl phosphate in trioctylmethylammonium chloride (Aliquat 336) or trihexyl(tetradecyl)phosphonium chloride (Cyphos 101) ionic liquids were studied. The extraction percentage of these actinides was measured as a function of a concentration of nitric or hydrochloric acid and a set combination of a room temperature ionic liquid and an extractant. The pure room temperature ionic liquids could extract the plutonium and uranium to various degrees, with the combinations with extractants affecting the extraction percentages further. The 100 % extraction efficiency of plutonium was achieved across all concentrations of HCl with the combinations of Cyphos 101 and malonamide. 100% extraction efficiency of uranium was achieved by Cyphos 101 and malonamide from distilled water. Americium was not extracted by any combination under any conditions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20305 - Nuclear related engineering; (nuclear physics to be 1.3);
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Technology & Radiation Protection
ISSN
1451-3994
e-ISSN
1452-8185
Svazek periodika
2
Číslo periodika v rámci svazku
39
Stát vydavatele periodika
RS - Srbská republika
Počet stran výsledku
8
Strana od-do
138-145
Kód UT WoS článku
001359987300006
EID výsledku v databázi Scopus
2-s2.0-85212950937