Determination of antioxidant activity and polyphenols content in chips by raman and IR spectroscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41210%2F17%3A74677" target="_blank" >RIV/60460709:41210/17:74677 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of antioxidant activity and polyphenols content in chips by raman and IR spectroscopy
Popis výsledku v původním jazyce
The application of vibrational spectroscopy for the determination of total polyphenols content, antioxidant activity, colour parameters, and fat level in chips originated from yellow-, red- and purple-fleshed potato varieties is reported. Raman, infrared (IR) and near-infrared (NIR) spectra of the laboratory-prepared chips were collected. Combining spectral data with the results of reference analyses, partial least squares regression models were built. To characterise and compare the elaborated models, the relative standard errors of prediction were calculated for calibration and validation sets. In the case of total phenolics quantification by Raman/IR/NIR techniques, these errors (%) amounted to 4,0/7,0/7,1 and 6,4/8,5/8,4 for calibration and validit ion samples, respectively, whereas they were 4,9/7,7/4,8 and 6,6/8,3/6,8 for antioxidant activity. The obtained results demonstrate that both infrared and Raman spectroscopy can effectively replace commonly used extraction methods. It follows that Ram
Název v anglickém jazyce
Determination of antioxidant activity and polyphenols content in chips by raman and IR spectroscopy
Popis výsledku anglicky
The application of vibrational spectroscopy for the determination of total polyphenols content, antioxidant activity, colour parameters, and fat level in chips originated from yellow-, red- and purple-fleshed potato varieties is reported. Raman, infrared (IR) and near-infrared (NIR) spectra of the laboratory-prepared chips were collected. Combining spectral data with the results of reference analyses, partial least squares regression models were built. To characterise and compare the elaborated models, the relative standard errors of prediction were calculated for calibration and validation sets. In the case of total phenolics quantification by Raman/IR/NIR techniques, these errors (%) amounted to 4,0/7,0/7,1 and 6,4/8,5/8,4 for calibration and validit ion samples, respectively, whereas they were 4,9/7,7/4,8 and 6,6/8,3/6,8 for antioxidant activity. The obtained results demonstrate that both infrared and Raman spectroscopy can effectively replace commonly used extraction methods. It follows that Ram
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
21101 - Food and beverages
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Food Analytical Methods
ISSN
1936-9751
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
3964-3971
Kód UT WoS článku
000415044900017
EID výsledku v databázi Scopus
2-s2.0-85021220762