Prescription versus over-the-counter venotonics: HPLC-DAD and static digestive mode simulation comparison
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41210%2F24%3A101173" target="_blank" >RIV/60460709:41210/24:101173 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.minervamedica.it/en/journals/international-angiology/article.php?cod=R34Y2024N05A0469" target="_blank" >https://www.minervamedica.it/en/journals/international-angiology/article.php?cod=R34Y2024N05A0469</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.23736/S0392-9590.24.05291-X" target="_blank" >10.23736/S0392-9590.24.05291-X</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Prescription versus over-the-counter venotonics: HPLC-DAD and static digestive mode simulation comparison
Popis výsledku v původním jazyce
Background: Venotonics are a class of therapeutically active molecules that have vaso-protective effects. They are used to alleviate venous diseases and disorders, particularly venous insufficiency. We compared the composition of prescription versus over-the-counter (OTC) venotonics using high-performance liquid chromatography with UV detection (HPLC-DAD) and simulating their digestion using a static digestive model. Methods: From each drug, five tablets were weighed. A homogenate was prepared, and 25 mg of crushed homogenized tablets were weighed into 25 ml volumetric flasks. Dissolved in MeOH and added two drops of saturated NaOH solution. The samples were filtered into vials (Teflon, 0.45 um) and used for analysis. An Ultimate 3000 HPLC system (Thermo Fisher Scientific, Waltham, MA, USA) consisting of a quaternization pump, autosampler, column thermostat and DAD (UV/VIS detector) was used. The composition of the mobile phase proceeded in a linear gradient from 30% methanol and 70% phosphoric acid (0.15%) in water at time t=0 min. to 80% methanol and 20% phosphoric acid (0.15%) at time t=15 min., at a constant mobile phase flow rate of 1.2 mL/min. Detection was performed using a DAD detector in the 190-450 nm wavelength range. The content of monitored flavonoids was calculated from peaks at a wavelength of 277 nm, in which both flavonoids have their absorption maxima. The static digestive model was used to simulate the digestive phase from the oral cavity to the corresponding intestinal phase. Results: The content of diosmin and hesperidin (mg per table) for a prescription drug: Detralex: 480 mg, 26 mg. The content of diosmin and hesperidin (mg per tablet) for OTC drugs: Venostop: 502 mg, 48 mg, Diosminol: 520 mg, 50 mg, Devenal: 496 mg, 49 mg, Diohes: 493 mg, 46 mg. Digestion did not affect the solubility of all tested drugs. The active substances could not be determined in the non-alkalized sample. After alkalization, part of the insoluble matter was visibly dissolved and converted to a yellow flavonoid complex. Neither diosmin nor hesperidin could be identified afterwards. Conclusions: Our experimental results show that the contents of both listed active substances, diosmin and hesperidin, met the declared amounts in all tested medicaments. Digestion simulation showed identical behaviour in prescription and OTC venotonics. The active substances could not be determined in the non alkalized sample. Digestion did not affect the solubility of the tested drugs.
Název v anglickém jazyce
Prescription versus over-the-counter venotonics: HPLC-DAD and static digestive mode simulation comparison
Popis výsledku anglicky
Background: Venotonics are a class of therapeutically active molecules that have vaso-protective effects. They are used to alleviate venous diseases and disorders, particularly venous insufficiency. We compared the composition of prescription versus over-the-counter (OTC) venotonics using high-performance liquid chromatography with UV detection (HPLC-DAD) and simulating their digestion using a static digestive model. Methods: From each drug, five tablets were weighed. A homogenate was prepared, and 25 mg of crushed homogenized tablets were weighed into 25 ml volumetric flasks. Dissolved in MeOH and added two drops of saturated NaOH solution. The samples were filtered into vials (Teflon, 0.45 um) and used for analysis. An Ultimate 3000 HPLC system (Thermo Fisher Scientific, Waltham, MA, USA) consisting of a quaternization pump, autosampler, column thermostat and DAD (UV/VIS detector) was used. The composition of the mobile phase proceeded in a linear gradient from 30% methanol and 70% phosphoric acid (0.15%) in water at time t=0 min. to 80% methanol and 20% phosphoric acid (0.15%) at time t=15 min., at a constant mobile phase flow rate of 1.2 mL/min. Detection was performed using a DAD detector in the 190-450 nm wavelength range. The content of monitored flavonoids was calculated from peaks at a wavelength of 277 nm, in which both flavonoids have their absorption maxima. The static digestive model was used to simulate the digestive phase from the oral cavity to the corresponding intestinal phase. Results: The content of diosmin and hesperidin (mg per table) for a prescription drug: Detralex: 480 mg, 26 mg. The content of diosmin and hesperidin (mg per tablet) for OTC drugs: Venostop: 502 mg, 48 mg, Diosminol: 520 mg, 50 mg, Devenal: 496 mg, 49 mg, Diohes: 493 mg, 46 mg. Digestion did not affect the solubility of all tested drugs. The active substances could not be determined in the non-alkalized sample. After alkalization, part of the insoluble matter was visibly dissolved and converted to a yellow flavonoid complex. Neither diosmin nor hesperidin could be identified afterwards. Conclusions: Our experimental results show that the contents of both listed active substances, diosmin and hesperidin, met the declared amounts in all tested medicaments. Digestion simulation showed identical behaviour in prescription and OTC venotonics. The active substances could not be determined in the non alkalized sample. Digestion did not affect the solubility of the tested drugs.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
30100 - Basic medicine
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
INTERNATIONAL ANGIOLOGY
ISSN
0392-9590
e-ISSN
0392-9590
Svazek periodika
43
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
469-475
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85211353604