Effects on the Indoor Environment in a Stable for Horses in Winter: A Case Study.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41210%2F24%3A98095" target="_blank" >RIV/60460709:41210/24:98095 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60460709:41310/24:98095
Výsledek na webu
<a href="https://www.mdpi.com/2077-0472/14/8/1287" target="_blank" >https://www.mdpi.com/2077-0472/14/8/1287</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/agriculture14081287" target="_blank" >10.3390/agriculture14081287</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effects on the Indoor Environment in a Stable for Horses in Winter: A Case Study.
Popis výsledku v původním jazyce
The aim of this article is to show the most significant factors influencing the indoor environment in winter considering the operating conditions of an older stable modified for housing 12 horses and an indoor riding arena for teaching and sports purposes. This research focused on assessing the influences affecting the internal environment from the point of view of the construction of the building and ventilation control in the operating conditions of working and non-working days. The analysis of the results showed that the massive masonry structure has sufficient thermal insulation and accumulation, which was manifested by good temperature stability inside the stable of 7.2 +/- 1.7 degrees C when the outside air temperature was -4.80 +/- 1.5 degrees C. At low outdoor air temperatures of -6.44 +/- 0.4 degrees C, the following conditions were found: a higher relative air humidity (76.0 +/- 5.3%), a high CO2 concentration 2317.1 +/- 931.7 ppm, and a high airborne dust concentration PM10 = 231.94 +/- 19.13 mu gm-3 and PM2.5 = 160.13 +/- 6.28 mu gm-3. Therefore, it is necessary to improve the solution and function of the stable ventilation. The small size of the windows and their uneven distribution (average daylight factor ei from 0.313 +/- 0.154 to 0.835 +/- 0.309) caused insufficient daylight in some individual boxes.
Název v anglickém jazyce
Effects on the Indoor Environment in a Stable for Horses in Winter: A Case Study.
Popis výsledku anglicky
The aim of this article is to show the most significant factors influencing the indoor environment in winter considering the operating conditions of an older stable modified for housing 12 horses and an indoor riding arena for teaching and sports purposes. This research focused on assessing the influences affecting the internal environment from the point of view of the construction of the building and ventilation control in the operating conditions of working and non-working days. The analysis of the results showed that the massive masonry structure has sufficient thermal insulation and accumulation, which was manifested by good temperature stability inside the stable of 7.2 +/- 1.7 degrees C when the outside air temperature was -4.80 +/- 1.5 degrees C. At low outdoor air temperatures of -6.44 +/- 0.4 degrees C, the following conditions were found: a higher relative air humidity (76.0 +/- 5.3%), a high CO2 concentration 2317.1 +/- 931.7 ppm, and a high airborne dust concentration PM10 = 231.94 +/- 19.13 mu gm-3 and PM2.5 = 160.13 +/- 6.28 mu gm-3. Therefore, it is necessary to improve the solution and function of the stable ventilation. The small size of the windows and their uneven distribution (average daylight factor ei from 0.313 +/- 0.154 to 0.835 +/- 0.309) caused insufficient daylight in some individual boxes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
40101 - Agriculture
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agriculture-BASEL
ISSN
2077-0472
e-ISSN
2077-0472
Svazek periodika
14
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
26
Strana od-do
1-26
Kód UT WoS článku
001305528500001
EID výsledku v databázi Scopus
2-s2.0-85202654528