The Challenge of Cleaning Direct-Injection Systems for Pesticide Application
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F12%3A58695" target="_blank" >RIV/60460709:41310/12:58695 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Challenge of Cleaning Direct-Injection Systems for Pesticide Application
Popis výsledku v původním jazyce
A direct injection system (DIS) for pesticide injection at all nozzles was set up in order to ascertain its ability to be cleaned. Under laboratory conditions, the system was contaminated with a safe-to-use salty polyvinylpyrrolidonewater solution as a test pesticide and then cleaned in two steps: (1) reclaiming the test pesticide by pushing it back into the pesticide tank using pressurized air (pre-cleaning) and (2) rinsing the contaminated part of the hydraulic system with water. Tests on a 3 m wide test bench included gravimetric and conductivity measurements to determine the amount of residues in the test section and test pesticide concentrations in the rinsing water. Mechanical action inside the test section was varied by (1) increasing the air pressure for pre-cleaning, (2) increasing the rinsing water pressure, and (3) employing pulsed water-air flow. Initial test pesticide concentrations in the rinsing water could be as high as 25%, which is more than in common spray mixes and
Název v anglickém jazyce
The Challenge of Cleaning Direct-Injection Systems for Pesticide Application
Popis výsledku anglicky
A direct injection system (DIS) for pesticide injection at all nozzles was set up in order to ascertain its ability to be cleaned. Under laboratory conditions, the system was contaminated with a safe-to-use salty polyvinylpyrrolidonewater solution as a test pesticide and then cleaned in two steps: (1) reclaiming the test pesticide by pushing it back into the pesticide tank using pressurized air (pre-cleaning) and (2) rinsing the contaminated part of the hydraulic system with water. Tests on a 3 m wide test bench included gravimetric and conductivity measurements to determine the amount of residues in the test section and test pesticide concentrations in the rinsing water. Mechanical action inside the test section was varied by (1) increasing the air pressure for pre-cleaning, (2) increasing the rinsing water pressure, and (3) employing pulsed water-air flow. Initial test pesticide concentrations in the rinsing water could be as high as 25%, which is more than in common spray mixes and
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Transactions of the ASABE
ISSN
2151-0032
e-ISSN
—
Svazek periodika
55
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
1643-1650
Kód UT WoS článku
000311330100001
EID výsledku v databázi Scopus
—