Popis výsledku v původním jazyce
The article presents the measurement results of the relaxation of long-term loaded compression springs manufactured out of non-alloy steel. During the relaxation test that lasted one year in a laboratory with a temperature of 22 oC, initial shear stressset at a value of 30 % of the ultimate tensile strength of the material, decreased the strength of the springs with a wire diameter of 1 mm by 4.0 %, springs with a wire diameter of 3.15 mm by 3.1 %, and springs with a wire diameter of 5 mm by 1.6 %. Bylowering the initial shear stress to a value of only 14 % of the ultimate tensile strength of the material, no relaxation greater than 1.1 % was recorded in any of the springs during measuring. This initial shear stress value is recommended as a maximumin applications where the relaxation of statically loaded springs manufactured out of carbon steel has a significant impact on the operation of the device.
Název v anglickém jazyce
THE RELAXATION OF STATICALLY LOADED COMPRESSION SPRINGS
Popis výsledku anglicky
The article presents the measurement results of the relaxation of long-term loaded compression springs manufactured out of non-alloy steel. During the relaxation test that lasted one year in a laboratory with a temperature of 22 oC, initial shear stressset at a value of 30 % of the ultimate tensile strength of the material, decreased the strength of the springs with a wire diameter of 1 mm by 4.0 %, springs with a wire diameter of 3.15 mm by 3.1 %, and springs with a wire diameter of 5 mm by 1.6 %. Bylowering the initial shear stress to a value of only 14 % of the ultimate tensile strength of the material, no relaxation greater than 1.1 % was recorded in any of the springs during measuring. This initial shear stress value is recommended as a maximumin applications where the relaxation of statically loaded springs manufactured out of carbon steel has a significant impact on the operation of the device.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
5th International Conference onTrends in Agricultural Engineering 2013, TAE 2013
ISBN
978-80-213-2388-9
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
602-606
Název nakladatele
Czech University of Life Sciences Prague
Místo vydání
Prague
Místo konání akce
Prague
Datum konání akce
3. 9. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000345059700118