CFD model of regenerative heat exchanger
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F15%3A67347" target="_blank" >RIV/60460709:41310/15:67347 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CFD model of regenerative heat exchanger
Popis výsledku v původním jazyce
This paper is focused on the computational fluid dynamics (CFD) modeling of regenerative heat exchanger suitable for animal houses. Buildings used for housing of animals in farms with intensive breeding, like poultry or pig houses, are characterized by high generation of heat inside, partly produced by animals, and in the case of small young animals, supplemented also by heating. On the other side these buildings need intensive ventilation which causes big losses of energy by exhausted air. A good way how to reduce heat losses can be the use of technical systems of heat recovery. There are two principal constructions of heat exchangers for heat recovery. There are either recuperative or regenerative heat exchangers. Industrially produced heat exchangers, commonly used in residential or industrial buildings, can be used in agricultural conditions only with difficulties, mainly because of the high dust concentration, which is extremely high in animal houses. CFD modeling was used to calc
Název v anglickém jazyce
CFD model of regenerative heat exchanger
Popis výsledku anglicky
This paper is focused on the computational fluid dynamics (CFD) modeling of regenerative heat exchanger suitable for animal houses. Buildings used for housing of animals in farms with intensive breeding, like poultry or pig houses, are characterized by high generation of heat inside, partly produced by animals, and in the case of small young animals, supplemented also by heating. On the other side these buildings need intensive ventilation which causes big losses of energy by exhausted air. A good way how to reduce heat losses can be the use of technical systems of heat recovery. There are two principal constructions of heat exchangers for heat recovery. There are either recuperative or regenerative heat exchangers. Industrially produced heat exchangers, commonly used in residential or industrial buildings, can be used in agricultural conditions only with difficulties, mainly because of the high dust concentration, which is extremely high in animal houses. CFD modeling was used to calc
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GB - Zemědělské stroje a stavby
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agricultural Engineering International: CIGR Journal
ISSN
1682-1130
e-ISSN
—
Svazek periodika
2015
Číslo periodika v rámci svazku
N
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
14
Strana od-do
80-93
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—