CHANGES IN TEMPERATURE AND ENERGY IN THE GROUND MASS WITH LINEAR HORIZONTAL HEAT EXCHANGER
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F16%3A72784" target="_blank" >RIV/60460709:41310/16:72784 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21720/16:00310668
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CHANGES IN TEMPERATURE AND ENERGY IN THE GROUND MASS WITH LINEAR HORIZONTAL HEAT EXCHANGER
Popis výsledku v původním jazyce
The aim of the verifications was to analyze the temperature changes of the ground mass with linear HGHE in the heating period, determine the values of the heat flows and energies extracted from the ground mass via linear HGHE and evaluate the temperature regeneration of the ground mass during the HGHE stagnation. The linear HGHE is made from polyethylene piping PE 100RC 40x3,7 mm. HGHE with a total length of 330 m was installed at a depth of 1,8 m in three loops with a spacing of 1 m. Monitoring and analysing the linear HGHE showed that the average daily ground mass temperatures with linear HGHE were above zero in the heating season and energy extraction from the ground mass reached 16,98 kWh.m(-2). Temperature difference of the ground mass within the linear HGHE area at the beginning of the heating seasons 2013/2014 and 2012/2013 was quite insignificant.
Název v anglickém jazyce
CHANGES IN TEMPERATURE AND ENERGY IN THE GROUND MASS WITH LINEAR HORIZONTAL HEAT EXCHANGER
Popis výsledku anglicky
The aim of the verifications was to analyze the temperature changes of the ground mass with linear HGHE in the heating period, determine the values of the heat flows and energies extracted from the ground mass via linear HGHE and evaluate the temperature regeneration of the ground mass during the HGHE stagnation. The linear HGHE is made from polyethylene piping PE 100RC 40x3,7 mm. HGHE with a total length of 330 m was installed at a depth of 1,8 m in three loops with a spacing of 1 m. Monitoring and analysing the linear HGHE showed that the average daily ground mass temperatures with linear HGHE were above zero in the heating season and energy extraction from the ground mass reached 16,98 kWh.m(-2). Temperature difference of the ground mass within the linear HGHE area at the beginning of the heating seasons 2013/2014 and 2012/2013 was quite insignificant.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0091" target="_blank" >ED2.1.00/03.0091: Univerzitní centrum energeticky efektivních budov (UCEEB)</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PROCEEDING OF 6TH INTERNATIONAL CONFERENCE ON TRENDS IN AGRICULTURAL ENGINEERING 2016
ISBN
978-80-213-2683-5
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
425-432
Název nakladatele
CZECH UNIVERSITY OF LIFE SCIENCES PRAGUE
Místo vydání
Prague
Místo konání akce
PRAGUE
Datum konání akce
7. 9. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000390603400067