Energy consumption of milking pump controlled by frequency convertor during milking cycle
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F18%3A76952" target="_blank" >RIV/60460709:41310/18:76952 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.15159/AR.18.016" target="_blank" >http://dx.doi.org/10.15159/AR.18.016</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.15159/AR.18.016" target="_blank" >10.15159/AR.18.016</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Energy consumption of milking pump controlled by frequency convertor during milking cycle
Popis výsledku v původním jazyce
The article deals with selected parameters affecting the energy consumption of a vacuum pump in a milking system during the whole milking cycle in variants with and without regulation by a frequency convertor. When put into practice, the latest research of creation, control and stabilization of vacuum in milking devices allows dairy farmers to obtain a vacuum system that ensures maximum stability of milking pressure, which is a basic requirement affecting the health of dairy cows. The choice of vacuum system prioritizes in particular high performance, maximum operational reliability, minimum maintenance, long service life, environmental friendliness and economy. The vacuum pump was a Roots vacuum pump with a rotary piston which is typical for this use. Use of a frequency convertor significantly affected the efficiency of this pump for control of vacuum pressure level and pump performance by varying the rotation frequency according to the actual airflow requirement. Using this control system, only as
Název v anglickém jazyce
Energy consumption of milking pump controlled by frequency convertor during milking cycle
Popis výsledku anglicky
The article deals with selected parameters affecting the energy consumption of a vacuum pump in a milking system during the whole milking cycle in variants with and without regulation by a frequency convertor. When put into practice, the latest research of creation, control and stabilization of vacuum in milking devices allows dairy farmers to obtain a vacuum system that ensures maximum stability of milking pressure, which is a basic requirement affecting the health of dairy cows. The choice of vacuum system prioritizes in particular high performance, maximum operational reliability, minimum maintenance, long service life, environmental friendliness and economy. The vacuum pump was a Roots vacuum pump with a rotary piston which is typical for this use. Use of a frequency convertor significantly affected the efficiency of this pump for control of vacuum pressure level and pump performance by varying the rotation frequency according to the actual airflow requirement. Using this control system, only as
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
40101 - Agriculture
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agronomy Research
ISSN
1406-894X
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
10
Strana od-do
297-306
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85048342017