Parameters setting of Frequency Converter PI regulation to ensure the vacuum of the milking process
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F21%3A10247725" target="_blank" >RIV/61989100:27240/21:10247725 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43110/21:43919983 RIV/62156489:43210/21:43919983
Výsledek na webu
<a href="https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0253427" target="_blank" >https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0253427</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0253427" target="_blank" >10.1371/journal.pone.0253427</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Parameters setting of Frequency Converter PI regulation to ensure the vacuum of the milking process
Popis výsledku v původním jazyce
This paper presents regulation of an asynchronous induction motor so as to create a stable vacuum milk pump using Variable Frequency Drive (VFD). Contribution includes providing information about the usage of the VFD, which regulates the activity of an asynchronous induction motor so that the vacuum pump milking machine creates stable vacuum. The paper describes the functional and time dependence of input values and output parameters of frequency converters at changing electric motor speed. For simulation and verification the milking process a mathematical model of the milking machine was created. The simulation was verified in Matlab/Simulink software. The constructed mathematical model showed symmetric regulation. Control model symmetry was verified at the laboratory of milking machine. The possibility to remove the control valve from milking equipment was proven using the measured data. It was found that constant vacuum values can be maintained. A constant vacuum can be maintained by changing vacuum pump speed. This control is of an accepted standard (ISO 5707: 2007). The power saving control values (on the milking equipment) of the VFD were positive throughout the measuring range. The performance of the milking vacuum pump is normally designed from the maximum air consumption of the milking machine at nominal vacuum (50 kPa), and a performance reserve is added to this. This means that the pump is operated between the ranges 7.53 and 15.06 dm(3) s(-1). By using a vacuum pump controlled by a VFD, power savings can be achieved from 32.50% to 54.02% compared to a control valve.
Název v anglickém jazyce
Parameters setting of Frequency Converter PI regulation to ensure the vacuum of the milking process
Popis výsledku anglicky
This paper presents regulation of an asynchronous induction motor so as to create a stable vacuum milk pump using Variable Frequency Drive (VFD). Contribution includes providing information about the usage of the VFD, which regulates the activity of an asynchronous induction motor so that the vacuum pump milking machine creates stable vacuum. The paper describes the functional and time dependence of input values and output parameters of frequency converters at changing electric motor speed. For simulation and verification the milking process a mathematical model of the milking machine was created. The simulation was verified in Matlab/Simulink software. The constructed mathematical model showed symmetric regulation. Control model symmetry was verified at the laboratory of milking machine. The possibility to remove the control valve from milking equipment was proven using the measured data. It was found that constant vacuum values can be maintained. A constant vacuum can be maintained by changing vacuum pump speed. This control is of an accepted standard (ISO 5707: 2007). The power saving control values (on the milking equipment) of the VFD were positive throughout the measuring range. The performance of the milking vacuum pump is normally designed from the maximum air consumption of the milking machine at nominal vacuum (50 kPa), and a performance reserve is added to this. This means that the pump is operated between the ranges 7.53 and 15.06 dm(3) s(-1). By using a vacuum pump controlled by a VFD, power savings can be achieved from 32.50% to 54.02% compared to a control valve.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_019%2F0000867" target="_blank" >EF16_019/0000867: Centrum výzkumu pokročilých mechatronických systémů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
PLoS One
ISSN
1932-6203
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
17
Strana od-do
—
Kód UT WoS článku
000668791400071
EID výsledku v databázi Scopus
—