Importance of microclimate conditions and CO2 control in educational buildings: A case study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41310%2F18%3A78183" target="_blank" >RIV/60460709:41310/18:78183 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.15159/AR.18.157" target="_blank" >http://dx.doi.org/10.15159/AR.18.157</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.15159/AR.18.157" target="_blank" >10.15159/AR.18.157</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Importance of microclimate conditions and CO2 control in educational buildings: A case study
Popis výsledku v původním jazyce
Current efforts to minimize energy losses and maximize energy savings for heating of all houses are most often gained by insulating facades and replacing windows. However, these measures can have a significant negative impact on human health and these problems can occur in buildings with a high concentration of people, such as school buildings. The aim of this paper is to analyse the results of measurements of air temperature, relative air humidity and carbon dioxide in winter period in the classrooms of two universities, Estonian University of Life Sciences (EULS) in Tartu and Czech University of Life Sciences (CULS) in Prague. The measurements have carried out in eight classrooms of the EULS and two classrooms of the CULS. The external and internal temperature, relative humidity and concentration of carbon dioxide have measured in the classrooms during a few days in the winter period. In the lecture rooms of CULS, when the air conditioning was off, the levels of CO2 exceeded the recommended levels
Název v anglickém jazyce
Importance of microclimate conditions and CO2 control in educational buildings: A case study
Popis výsledku anglicky
Current efforts to minimize energy losses and maximize energy savings for heating of all houses are most often gained by insulating facades and replacing windows. However, these measures can have a significant negative impact on human health and these problems can occur in buildings with a high concentration of people, such as school buildings. The aim of this paper is to analyse the results of measurements of air temperature, relative air humidity and carbon dioxide in winter period in the classrooms of two universities, Estonian University of Life Sciences (EULS) in Tartu and Czech University of Life Sciences (CULS) in Prague. The measurements have carried out in eight classrooms of the EULS and two classrooms of the CULS. The external and internal temperature, relative humidity and concentration of carbon dioxide have measured in the classrooms during a few days in the winter period. In the lecture rooms of CULS, when the air conditioning was off, the levels of CO2 exceeded the recommended levels
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
50704 - Environmental sciences (social aspects)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Agronomy Research
ISSN
1406-894X
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
10
Strana od-do
1771-1780
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85059659189