Development of a fast UHPLC-MS/MS for the analysis of selected priority micropollutants in wastewater samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60460709%3A41330%2F19%3A79758" target="_blank" >RIV/60460709:41330/19:79758 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.tandfonline.com/doi/full/10.1080/03067319.2019.1660874" target="_blank" >https://www.tandfonline.com/doi/full/10.1080/03067319.2019.1660874</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/03067319.2019.1660874" target="_blank" >10.1080/03067319.2019.1660874</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of a fast UHPLC-MS/MS for the analysis of selected priority micropollutants in wastewater samples
Popis výsledku v původním jazyce
In recent years, there have been many reports on the presence of organic compounds in different compartments of the aquatic environment. The subject of our research was the development of a new method for the determination of selected organic micropollutants and their transformation products in wastewater samples. A rapid and sensitive ultra-high performance liquid chromatographic method coupled with tandem mass spectrometry has been developed and used for the separation and determination of 1H-benzotriazole, imidacloprid and clarithromycin in wastewater samples. The analytes were separated on a ZORBAX SB-C3 column with a gradient elution within 3,0 min. The analytes were isolated from wastewater samples by solid-phase extraction. Extraction was carried out on the Oasis HLB cartridges and methanol:acetone (1:1, v/v) was used for elution. The working ranges of the developed method were 1-100 ng L-1. The recovery ranged from 62% to 102% and intra- and inter-day precision was lower than 13% for all anal
Název v anglickém jazyce
Development of a fast UHPLC-MS/MS for the analysis of selected priority micropollutants in wastewater samples
Popis výsledku anglicky
In recent years, there have been many reports on the presence of organic compounds in different compartments of the aquatic environment. The subject of our research was the development of a new method for the determination of selected organic micropollutants and their transformation products in wastewater samples. A rapid and sensitive ultra-high performance liquid chromatographic method coupled with tandem mass spectrometry has been developed and used for the separation and determination of 1H-benzotriazole, imidacloprid and clarithromycin in wastewater samples. The analytes were separated on a ZORBAX SB-C3 column with a gradient elution within 3,0 min. The analytes were isolated from wastewater samples by solid-phase extraction. Extraction was carried out on the Oasis HLB cartridges and methanol:acetone (1:1, v/v) was used for elution. The working ranges of the developed method were 1-100 ng L-1. The recovery ranged from 62% to 102% and intra- and inter-day precision was lower than 13% for all anal
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Environmental Analytical Chemistry
ISSN
0306-7319
e-ISSN
1029-0397
Svazek periodika
2019
Číslo periodika v rámci svazku
N
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
20
Strana od-do
1-20
Kód UT WoS článku
000485959600001
EID výsledku v databázi Scopus
2-s2.0-85072046649