Positively and negatively charged xylan films
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F11%3A43891601" target="_blank" >RIV/60461373:22310/11:43891601 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Positively and negatively charged xylan films
Popis výsledku v původním jazyce
Xylan was 2-hydroxypropylsulfonated and/or 2-hydroxypropylquaternized for film application All the products were water soluble with molar masses of the derivatives between M(n) of 3 8 and 948 9 kg/mol with polydispersity index D from 1 7 to 268 At the range from 100 to 250 mu m of thickness the material developed reproducible mechanical properties When mixed solutions of quaternized and sulfonated samples were used for film preparation they disrupted although their thickness was 234+/-18 mu m as determined by SEM The thermal and thermo-oxidative stability of the mixed derivative increased in comparison to unmodified xylan film as determined by TG and DTA analysis The measured tensile strength values were the best on quaternized films (64 3 MPa) while the Young s modulus values were higher on hydroxypropylsulfonated xylan film (3350 MPa) The mixed derivative gave values close to average between the two derivatives and according to SEM observation also the smoothest surface on the fractu
Název v anglickém jazyce
Positively and negatively charged xylan films
Popis výsledku anglicky
Xylan was 2-hydroxypropylsulfonated and/or 2-hydroxypropylquaternized for film application All the products were water soluble with molar masses of the derivatives between M(n) of 3 8 and 948 9 kg/mol with polydispersity index D from 1 7 to 268 At the range from 100 to 250 mu m of thickness the material developed reproducible mechanical properties When mixed solutions of quaternized and sulfonated samples were used for film preparation they disrupted although their thickness was 234+/-18 mu m as determined by SEM The thermal and thermo-oxidative stability of the mixed derivative increased in comparison to unmodified xylan film as determined by TG and DTA analysis The measured tensile strength values were the best on quaternized films (64 3 MPa) while the Young s modulus values were higher on hydroxypropylsulfonated xylan film (3350 MPa) The mixed derivative gave values close to average between the two derivatives and according to SEM observation also the smoothest surface on the fractu
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CD - Makromolekulární chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Carbohydrate Polymers
ISSN
0144-8617
e-ISSN
—
Svazek periodika
83
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
769-775
Kód UT WoS článku
000285437000062
EID výsledku v databázi Scopus
—