Kinetics of zinc corrosion in concrete as a function of water and oxygen availability
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F19%3A43919478" target="_blank" >RIV/60461373:22310/19:43919478 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21610/19:00335554
Výsledek na webu
<a href="https://apps.webofknowledge.com/full_record.do?product=WOS&search_mode=GeneralSearch&qid=6&SID=F5NLzuzGLCBdXnZd1Z8&page=1&doc=5" target="_blank" >https://apps.webofknowledge.com/full_record.do?product=WOS&search_mode=GeneralSearch&qid=6&SID=F5NLzuzGLCBdXnZd1Z8&page=1&doc=5</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/ma12172786" target="_blank" >10.3390/ma12172786</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Kinetics of zinc corrosion in concrete as a function of water and oxygen availability
Popis výsledku v původním jazyce
This paper studies the effect of water as an oxidation agent and also of oxygen on zinc corrosion kinetics in active state in concrete, using high-sensitivity electrical resistance sensors. It was proven that zinc corrosion in active state is strongly affected by the presence of water at its surface. Zinc corrosion in real concrete in the absence of water can be misinterpreted as salt passivity. The presence of oxygen results in an increase of zinc corrosion rate, however at pH 12.6, passivity can occur. It was verified that corrosion products consisting primarily of Ca[Zn(OH)3]2·2H2O cannot effectively passivate zinc surface in concrete, even after 1800 h of exposure and zinc, or hot-dip galvanized steel can corrode at an unacceptable corrosion rate (more than 4 μm·a-1)
Název v anglickém jazyce
Kinetics of zinc corrosion in concrete as a function of water and oxygen availability
Popis výsledku anglicky
This paper studies the effect of water as an oxidation agent and also of oxygen on zinc corrosion kinetics in active state in concrete, using high-sensitivity electrical resistance sensors. It was proven that zinc corrosion in active state is strongly affected by the presence of water at its surface. Zinc corrosion in real concrete in the absence of water can be misinterpreted as salt passivity. The presence of oxygen results in an increase of zinc corrosion rate, however at pH 12.6, passivity can occur. It was verified that corrosion products consisting primarily of Ca[Zn(OH)3]2·2H2O cannot effectively passivate zinc surface in concrete, even after 1800 h of exposure and zinc, or hot-dip galvanized steel can corrode at an unacceptable corrosion rate (more than 4 μm·a-1)
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA17-22796S" target="_blank" >GA17-22796S: Experimentální a numerická analýza soudržnosti kovové výztuže s ultra vysokohodnotným betonem (UHPC) za vysokých teplot</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Materials
ISSN
1996-1944
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
17
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
13
Strana od-do
1-13
Kód UT WoS článku
000488880300139
EID výsledku v databázi Scopus
2-s2.0-85071845074