Název v původním jazyce
Mechanical properties, corrosion behaviour and biocompatibility of TiNbTaSn for dentistry
Popis výsledku v původním jazyce
Titanium and the alloy Ti-6Al-4V are standard in implantology, despite the fact that the alloys may suffer from biomechanical incompatibility. The appropriate solution is the use of titanium beta-alloys with a low modulus of elasticity and high strength. An additional advantage of these alloys is improved corrosion behaviour in environments that may contain fluoride ions, i.e. the oral cavity. Ti-25Nb-4Ta-(X)Sn alloys, where X is 4, 6, 8 and 10 weight per cent, were prepared. The phase composition, ultimate tensile strength, yield strength, Young modulus, elongation and hardness were measured. The corrosion behaviour in physiological saline, acidified physiological saline with and without the fluoride ions, was determined using, potentiodynamic polarization and electrochemical impedance spectroscopy. Bioactivity was predicted on the base of exposure in the simulated body fluid extended by impedance detection of the Ca/P layer formation. From the point of view of mechanical properties, alloys with a higher tin content are ideal for load-bearing applications. The corrosion resistance of these alloys in physiological saline is similar to titanium and significantly higher in the fluoride ions containing environment. The bioactivity test - exposure in SBF has shown quite identical results of the studied alloys and titanium, both in terms of kinetics and total composition of precipitated calcium-phosphate layer. Possible cytotoxicity effects were excluded by the exposure with murine fibroblasts. This study describes the mechanical properties and corrosion resistance in non-fluoride and fluoride containing media, predicts bioactivity and verifies non-cytotoxicity of new titanium alloys and demonstrates that they are a suitable substitute for currently the most widely used alloys (Ti-6Al-4V, Ti-6Al-7Nb) in terms of both mechanical properties and corrosion resistance for dental implants.
Název v anglickém jazyce
Mechanical properties, corrosion behaviour and biocompatibility of TiNbTaSn for dentistry
Popis výsledku anglicky
Titanium and the alloy Ti-6Al-4V are standard in implantology, despite the fact that the alloys may suffer from biomechanical incompatibility. The appropriate solution is the use of titanium beta-alloys with a low modulus of elasticity and high strength. An additional advantage of these alloys is improved corrosion behaviour in environments that may contain fluoride ions, i.e. the oral cavity. Ti-25Nb-4Ta-(X)Sn alloys, where X is 4, 6, 8 and 10 weight per cent, were prepared. The phase composition, ultimate tensile strength, yield strength, Young modulus, elongation and hardness were measured. The corrosion behaviour in physiological saline, acidified physiological saline with and without the fluoride ions, was determined using, potentiodynamic polarization and electrochemical impedance spectroscopy. Bioactivity was predicted on the base of exposure in the simulated body fluid extended by impedance detection of the Ca/P layer formation. From the point of view of mechanical properties, alloys with a higher tin content are ideal for load-bearing applications. The corrosion resistance of these alloys in physiological saline is similar to titanium and significantly higher in the fluoride ions containing environment. The bioactivity test - exposure in SBF has shown quite identical results of the studied alloys and titanium, both in terms of kinetics and total composition of precipitated calcium-phosphate layer. Possible cytotoxicity effects were excluded by the exposure with murine fibroblasts. This study describes the mechanical properties and corrosion resistance in non-fluoride and fluoride containing media, predicts bioactivity and verifies non-cytotoxicity of new titanium alloys and demonstrates that they are a suitable substitute for currently the most widely used alloys (Ti-6Al-4V, Ti-6Al-7Nb) in terms of both mechanical properties and corrosion resistance for dental implants.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Materials Research Express
ISSN
2053-1591
e-ISSN
—
Svazek periodika
7
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
13
Strana od-do
—
Kód UT WoS článku
000508225400001
EID výsledku v databázi Scopus
—