Comparison of different methods for assessing the pozzolanic activity of fly ash and bottom ash
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F23%3A43927260" target="_blank" >RIV/60461373:22310/23:43927260 - isvavai.cz</a>
Výsledek na webu
<a href="https://pubs.aip.org/aip/acp/article/2780/1/020023/2907204/Comparison-of-different-methods-for-assessing-the?searchresult=1" target="_blank" >https://pubs.aip.org/aip/acp/article/2780/1/020023/2907204/Comparison-of-different-methods-for-assessing-the?searchresult=1</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/5.0137066" target="_blank" >10.1063/5.0137066</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of different methods for assessing the pozzolanic activity of fly ash and bottom ash
Popis výsledku v původním jazyce
The work deals with the comparison of pozzolanic activity of selected fly ash (FA) and bottom ash (BA) fromlignite power plants in the Czech Republic. Pozzolanic activity was determined by Frattini test, electrical conductivity testand strength activity index (SAI). The results of the Frattini test performed after 8 days according to ČSN EN 196-5 showedthat all ashes have pozzolanic activity. In addition, the electrical conductivity test shows significant differences in thereactivity of the ash during the first hours of hydration. SAI was determined on mortars with 25 % ash replacement forcement after 28 days of hydration. The results of pozzolanic activity test methods were compared with each other and thecorrelations of the methods are discussed.
Název v anglickém jazyce
Comparison of different methods for assessing the pozzolanic activity of fly ash and bottom ash
Popis výsledku anglicky
The work deals with the comparison of pozzolanic activity of selected fly ash (FA) and bottom ash (BA) fromlignite power plants in the Czech Republic. Pozzolanic activity was determined by Frattini test, electrical conductivity testand strength activity index (SAI). The results of the Frattini test performed after 8 days according to ČSN EN 196-5 showedthat all ashes have pozzolanic activity. In addition, the electrical conductivity test shows significant differences in thereactivity of the ash during the first hours of hydration. SAI was determined on mortars with 25 % ash replacement forcement after 28 days of hydration. The results of pozzolanic activity test methods were compared with each other and thecorrelations of the methods are discussed.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20101 - Civil engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/FW01010195" target="_blank" >FW01010195: Pokročilé výrobní technologie pro strategické využití a skladování vedlejších energetických produktů (VEP)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
AIP Conference Proceedings
ISSN
0094-243X
e-ISSN
1551-7616
Svazek periodika
2780
Číslo periodika v rámci svazku
020023
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
"020023-1"-"020023-8"
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85177062945