Functionalized 2D Germanene and Its Derivatives for Electrochemical Detection of Gut-Derived Metabolites in Human Serum
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F23%3A43927568" target="_blank" >RIV/60461373:22310/23:43927568 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/2673-4591/48/1/45" target="_blank" >https://www.mdpi.com/2673-4591/48/1/45</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/CSAC2023-14903" target="_blank" >10.3390/CSAC2023-14903</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Functionalized 2D Germanene and Its Derivatives for Electrochemical Detection of Gut-Derived Metabolites in Human Serum
Popis výsledku v původním jazyce
In this work, germanene and its derivatives (Ge-H, Ge-CH3, Ge-C3-CN) were explored as electrochemical impedimetric platforms to develop a competitive immunoassay for the direct detection of gut-derived metabolites, kynurenic acid (KA) and quinolinic acid (QA). The competition occurs between the free KA/QA standards and BSA-conjugated antigens for a fixed amount of primary antibody binding sites. This affects the electron transfer rate of the [Fe(CN)6]3-/4- redox couple and changes the charge transfer resistance (Rct) on the electrode surface. The impedimetric signal measured due to the change in Rct is then correlated to the KA and QA concentration.
Název v anglickém jazyce
Functionalized 2D Germanene and Its Derivatives for Electrochemical Detection of Gut-Derived Metabolites in Human Serum
Popis výsledku anglicky
In this work, germanene and its derivatives (Ge-H, Ge-CH3, Ge-C3-CN) were explored as electrochemical impedimetric platforms to develop a competitive immunoassay for the direct detection of gut-derived metabolites, kynurenic acid (KA) and quinolinic acid (QA). The competition occurs between the free KA/QA standards and BSA-conjugated antigens for a fixed amount of primary antibody binding sites. This affects the electron transfer rate of the [Fe(CN)6]3-/4- redox couple and changes the charge transfer resistance (Rct) on the electrode surface. The impedimetric signal measured due to the change in Rct is then correlated to the KA and QA concentration.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
10402 - Inorganic and nuclear chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GX19-26910X" target="_blank" >GX19-26910X: Chemie ve dvou dimenzích - za hranice grafenu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Engineering Proceedings
ISSN
2673-4591
e-ISSN
2673-4591
Svazek periodika
48
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—