Optimalizace parametrů pro měření VOC kanystrovým systémem.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22320%2F07%3A00018970" target="_blank" >RIV/60461373:22320/07:00018970 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Parameters Optimization for the Measurement of VOCs by Canister System
Popis výsledku v původním jazyce
With the growing concern for the quality of the environment demand for reliable and sensitive monitoring techniques for organic compounds in atmosphere has increased in the recent past. Canister sampling and analysis is becoming a widely accepted choicefor the measurement of volatile organic compounds (VOCs). Before carrying out any measurement it is necessary to optimize parameters in order to get reproducible results. In view of this, canister sampling technique was optimized for efficient measurement of various VOCs including sulfur and chlorinated compounds. For all studied compounds the optimum trap desorption temperature was found to be 225°C while for CCl4 the optimum temperature was lower and this compound shows decrease in response with the increase in trap desorption temperature. Other chloro compounds like chloroform and 1, 2-dichloroethane showed the same behavior as other organic compounds. Furthermore, cold trap desorption temperature and cryo injection time and moisture
Název v anglickém jazyce
Parameters Optimization for the Measurement of VOCs by Canister System
Popis výsledku anglicky
With the growing concern for the quality of the environment demand for reliable and sensitive monitoring techniques for organic compounds in atmosphere has increased in the recent past. Canister sampling and analysis is becoming a widely accepted choicefor the measurement of volatile organic compounds (VOCs). Before carrying out any measurement it is necessary to optimize parameters in order to get reproducible results. In view of this, canister sampling technique was optimized for efficient measurement of various VOCs including sulfur and chlorinated compounds. For all studied compounds the optimum trap desorption temperature was found to be 225°C while for CCl4 the optimum temperature was lower and this compound shows decrease in response with the increase in trap desorption temperature. Other chloro compounds like chloroform and 1, 2-dichloroethane showed the same behavior as other organic compounds. Furthermore, cold trap desorption temperature and cryo injection time and moisture
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DI - Znečištění a kontrola vzduchu
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Polish J. of Environ. Studies
ISSN
1230-1485
e-ISSN
—
Svazek periodika
16
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
841-846
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—