Evaluation of stability of volatile organic compounds in SUMMA canisters at different humidity levels
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22320%2F12%3A43893292" target="_blank" >RIV/60461373:22320/12:43893292 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of stability of volatile organic compounds in SUMMA canisters at different humidity levels
Popis výsledku v původním jazyce
Volatile organic compounds (VOC) occur in traces in atmosphere and even in trace levels, these compounds pose serious health hazard. Sample stability, recovery, effect of temperature and moisture management are a few critical points taken into consideration while sampling and analysis of polar and non polar VOCs. In the presnet work, stability study was carried out for polar and non polar VOCs in SUMMA stainless steel canister. Compounds recoveries were assended in dry and humid canisters. Canister samples were prepared with 0,25,50 and 100 % humidity. Moreover, the study with each humidity level was performed with two different concentrations (approx 50 &500 qgm3) of each compound to evaluate the influence of lower/higher concetration. Before startingexperiment, various parametres used for the measurement of VOCs from canister system were optimized and method detection limit was calculated as the accuracy of analytical measurement is the key part of stability study. Polar compounds l
Název v anglickém jazyce
Evaluation of stability of volatile organic compounds in SUMMA canisters at different humidity levels
Popis výsledku anglicky
Volatile organic compounds (VOC) occur in traces in atmosphere and even in trace levels, these compounds pose serious health hazard. Sample stability, recovery, effect of temperature and moisture management are a few critical points taken into consideration while sampling and analysis of polar and non polar VOCs. In the presnet work, stability study was carried out for polar and non polar VOCs in SUMMA stainless steel canister. Compounds recoveries were assended in dry and humid canisters. Canister samples were prepared with 0,25,50 and 100 % humidity. Moreover, the study with each humidity level was performed with two different concentrations (approx 50 &500 qgm3) of each compound to evaluate the influence of lower/higher concetration. Before startingexperiment, various parametres used for the measurement of VOCs from canister system were optimized and method detection limit was calculated as the accuracy of analytical measurement is the key part of stability study. Polar compounds l
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DI - Znečištění a kontrola vzduchu
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Research in Enviroment and Life Sciences
ISSN
0974-4908
e-ISSN
—
Svazek periodika
5
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
IN - Indická republika
Počet stran výsledku
8
Strana od-do
17-24
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—