Treatment of ammonia-polluted groundwatter in North Bohemian brown coal mining region - feasibility study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22320%2F11%3A43891811" target="_blank" >RIV/60461373:22320/11:43891811 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.5004/dwt.2011.2616" target="_blank" >http://dx.doi.org/10.5004/dwt.2011.2616</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5004/dwt.2011.2616" target="_blank" >10.5004/dwt.2011.2616</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Treatment of ammonia-polluted groundwatter in North Bohemian brown coal mining region - feasibility study
Popis výsledku v původním jazyce
A feasibility study was completed to assess the applicability of reverse osmosis technology at the site, where a brown coal processing plant released 4000 ton of ammonia into the subsurface during 20 years. The present groundwater ammonia concentration (approx. 100 ppm) was required to be reduced to 0.5 ppm to satisfy the Czech groundwater remediation directives. The reverse osmosis principle was examined within this study with the aim to confirm its capacity to reach the ammonia remediation limit as well as to provide cost estimation. The technological process was simulated by means of pilot-scale installation using samples of contaminated groundwater. Reverse osmosis clearly demonstrated its capacity to clean up the ammonia polluted groundwater to the limit demanded.
Název v anglickém jazyce
Treatment of ammonia-polluted groundwatter in North Bohemian brown coal mining region - feasibility study
Popis výsledku anglicky
A feasibility study was completed to assess the applicability of reverse osmosis technology at the site, where a brown coal processing plant released 4000 ton of ammonia into the subsurface during 20 years. The present groundwater ammonia concentration (approx. 100 ppm) was required to be reduced to 0.5 ppm to satisfy the Czech groundwater remediation directives. The reverse osmosis principle was examined within this study with the aim to confirm its capacity to reach the ammonia remediation limit as well as to provide cost estimation. The technological process was simulated by means of pilot-scale installation using samples of contaminated groundwater. Reverse osmosis clearly demonstrated its capacity to clean up the ammonia polluted groundwater to the limit demanded.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Desalination and Water Treatment
ISSN
1944-3994
e-ISSN
—
Svazek periodika
33
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
36-43
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—