Sorption of CrVI ions from aqueous solutions using anion exchange resins
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22320%2F13%3A43895494" target="_blank" >RIV/60461373:22320/13:43895494 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sorption of CrVI ions from aqueous solutions using anion exchange resins
Popis výsledku v původním jazyce
Batch and dynamic column experiments on anion exchangers with dimethylamin and trimethylammonium functional groups (Lewatit MonoPlus MP 64), DETA functional groups (Purolite A 830), trimethylammonium functional groups (Lewatit MP 500) and aminomethylglucitol functional groups (Purolite S 110) were performed. The influence of pH and coexisting ions on the efficiency of sorption of Cr was investigated. The ion exchange resin Lewatit MonoPlus MP 64 was also investigated for the effect of a flow rate on thecolumn efficiency of sorption of Cr. Optimal pH for sorption of CrVI using these ion exchange resins was found to be 3-4. The accompanying SO42- ions showed strongest negative influence on the sorption of CrVI. At column dynamic experiments regenerationof ion exchange resin Purolite A 830 was unsuccessful. Anion exchanger Lewatit MonoPlus MP 64 is suitable for repeated sorption of CrVI ions.
Název v anglickém jazyce
Sorption of CrVI ions from aqueous solutions using anion exchange resins
Popis výsledku anglicky
Batch and dynamic column experiments on anion exchangers with dimethylamin and trimethylammonium functional groups (Lewatit MonoPlus MP 64), DETA functional groups (Purolite A 830), trimethylammonium functional groups (Lewatit MP 500) and aminomethylglucitol functional groups (Purolite S 110) were performed. The influence of pH and coexisting ions on the efficiency of sorption of Cr was investigated. The ion exchange resin Lewatit MonoPlus MP 64 was also investigated for the effect of a flow rate on thecolumn efficiency of sorption of Cr. Optimal pH for sorption of CrVI using these ion exchange resins was found to be 3-4. The accompanying SO42- ions showed strongest negative influence on the sorption of CrVI. At column dynamic experiments regenerationof ion exchange resin Purolite A 830 was unsuccessful. Anion exchanger Lewatit MonoPlus MP 64 is suitable for repeated sorption of CrVI ions.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Ion Exchange Letters
ISSN
1803-4039
e-ISSN
—
Svazek periodika
6
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do