Colorimetric Determination of 2-Chlorobenzylidene Malonitrile in Gases and Liquids
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22320%2F23%3A43924212" target="_blank" >RIV/60461373:22320/23:43924212 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/23:00373293
Výsledek na webu
<a href="https://www.tandfonline.com/doi/full/10.1080/00032719.2022.2148684" target="_blank" >https://www.tandfonline.com/doi/full/10.1080/00032719.2022.2148684</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/00032719.2022.2148684" target="_blank" >10.1080/00032719.2022.2148684</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Colorimetric Determination of 2-Chlorobenzylidene Malonitrile in Gases and Liquids
Popis výsledku v původním jazyce
Here is described a new approach for the simple and rapid detection of 2-chlorobenzylidene malonitrile (CS riot control agent) based on the reaction with isatin (1H-indole-2,3-dione) and, alternatively, with ninhydrin (2,2-dihydroxy-1H-indene-1,3(2H)-dione), both in an environment of ammonium acetate, dimethyl sulfoxide, and dimethylformamide. The method was designed for the preparation of detection tubes for air analysis, test strips for the analysis of liquid samples, and for spectrophotometric determination. The use of ninhydrin appears to be more sensitive, but isatin provides higher stability and practical applicability.
Název v anglickém jazyce
Colorimetric Determination of 2-Chlorobenzylidene Malonitrile in Gases and Liquids
Popis výsledku anglicky
Here is described a new approach for the simple and rapid detection of 2-chlorobenzylidene malonitrile (CS riot control agent) based on the reaction with isatin (1H-indole-2,3-dione) and, alternatively, with ninhydrin (2,2-dihydroxy-1H-indene-1,3(2H)-dione), both in an environment of ammonium acetate, dimethyl sulfoxide, and dimethylformamide. The method was designed for the preparation of detection tubes for air analysis, test strips for the analysis of liquid samples, and for spectrophotometric determination. The use of ninhydrin appears to be more sensitive, but isatin provides higher stability and practical applicability.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ANALYTICAL LETTERS
ISSN
0003-2719
e-ISSN
1532-236X
Svazek periodika
56
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
1856-1867
Kód UT WoS článku
000891081800001
EID výsledku v databázi Scopus
2-s2.0-85142817777