Developmnet of chemiluminescent ELISAs to DDT and its metabolites in food and environmental samples
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F03%3A00008357" target="_blank" >RIV/60461373:22330/03:00008357 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Developmnet of chemiluminescent ELISAs to DDT and its metabolites in food and environmental samples
Popis výsledku v původním jazyce
Two enzyme-linked immunosorbent assays (ELISA) with chemiluminescent (CL) detection for the insecticide DDT and the group of DDT-related compounds have been optimized and characterized. Both conjugate-coated ELISAs are based on monoclonal antibodies (MAbs) of different specificity and homologous protein conjugates. Effects of several physicochemical factors (ionic strength, pH, Tween-20 and Bovine serum albumin (BSA) concentrations) and solvents (methanol, ethanol, acetone and N,N'-dimethylformamide) onthe performance of the assays were studied and optimized. For the DDT-selective assay, the sensitivity, estimated as the I-50 value, was 0.6 mug/l, with a linear working range between 0.1 and 2 mug/l and a limit of detection of 0.06 mug/l. For the DDT group-selective assay, the sensitivity was 0.2 mug/l, with a linear working range between 0.07 and 1 mug/l and a limit of detection of 0.04 mug/l. CL-ELISAs were four times more sensitive compared to colorimetric ELISAs. Finally, both immu
Název v anglickém jazyce
Developmnet of chemiluminescent ELISAs to DDT and its metabolites in food and environmental samples
Popis výsledku anglicky
Two enzyme-linked immunosorbent assays (ELISA) with chemiluminescent (CL) detection for the insecticide DDT and the group of DDT-related compounds have been optimized and characterized. Both conjugate-coated ELISAs are based on monoclonal antibodies (MAbs) of different specificity and homologous protein conjugates. Effects of several physicochemical factors (ionic strength, pH, Tween-20 and Bovine serum albumin (BSA) concentrations) and solvents (methanol, ethanol, acetone and N,N'-dimethylformamide) onthe performance of the assays were studied and optimized. For the DDT-selective assay, the sensitivity, estimated as the I-50 value, was 0.6 mug/l, with a linear working range between 0.1 and 2 mug/l and a limit of detection of 0.06 mug/l. For the DDT group-selective assay, the sensitivity was 0.2 mug/l, with a linear working range between 0.07 and 1 mug/l and a limit of detection of 0.04 mug/l. CL-ELISAs were four times more sensitive compared to colorimetric ELISAs. Finally, both immu
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF IMMUNOLOGICAL METHODS
ISSN
0022-1759
e-ISSN
—
Svazek periodika
283
Číslo periodika v rámci svazku
1-2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
13
Strana od-do
45-57