Stanovení N-methylkarbamátových pesticidů pomocí enzymové imunoanalýzy s chemiluminescenční detekcí
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F04%3A00012904" target="_blank" >RIV/60461373:22330/04:00012904 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Determination of N-methylcarbamate Pesticides Using Enzyme Immunoassays with Chemiluminescent Detection
Popis výsledku v původním jazyce
In the present work, enzyme-linked immunosorbent assays (ELISAs) with chemiluminescent detection for the determination of carbofuran, carbaryl and methiocarb were developed and the analytical parameters of these assays were compared with those of ELISAswith colorimetric detection. The sensitivity of immunochemical methods was expressed as detection limit, linear working range, and I50 value. In comparison with colorimetric ELISA, the ability of the chemiluminescent reagents to detect lower concentrations of HRP allowed to decrease the optimal antibody and conjugate concentrations and to reach better analytical parameters. The experimental comparison of the analytical performance of the ELISAs was carried out by analysing simply diluted fruit juices, spiked at different concentration levels with the above mentioned pesticides. Recovery values for both ELISAs were around 100 % and no matrix effects were observed when fruit juices were diluted 1:20 or more.
Název v anglickém jazyce
The Determination of N-methylcarbamate Pesticides Using Enzyme Immunoassays with Chemiluminescent Detection
Popis výsledku anglicky
In the present work, enzyme-linked immunosorbent assays (ELISAs) with chemiluminescent detection for the determination of carbofuran, carbaryl and methiocarb were developed and the analytical parameters of these assays were compared with those of ELISAswith colorimetric detection. The sensitivity of immunochemical methods was expressed as detection limit, linear working range, and I50 value. In comparison with colorimetric ELISA, the ability of the chemiluminescent reagents to detect lower concentrations of HRP allowed to decrease the optimal antibody and conjugate concentrations and to reach better analytical parameters. The experimental comparison of the analytical performance of the ELISAs was carried out by analysing simply diluted fruit juices, spiked at different concentration levels with the above mentioned pesticides. Recovery values for both ELISAs were around 100 % and no matrix effects were observed when fruit juices were diluted 1:20 or more.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Czech Journal of Food Science
ISBN
1212-1800
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
280-282
Název nakladatele
Česká akademie zemědělských věd
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
29. 9. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—